Literature DB >> 15340809

Normal values of volume flow in the internal carotid artery measured by a new angle-independent Doppler technique for evaluating cerebral perfusion.

K-M Schebesch1, S Simka, C Woertgen, A Brawanski, R D Rothoerl.   

Abstract

BACKGROUND: Cerebral blood flow is an important parameter when monitoring critically ill patients. Blood flow volume within the internal carotid artery (ICA) was shown to be correlated with the cerebral blood flow. The aim of our study was to provide normal values of the internal carotid artery volume flow using this new technology (QuantixND, Cardiosonix Ltd., Israel).
METHOD: The QuantixND System is an angle-independent Doppler system that employs two digital high resolution ultrasound heads within one probe in an defined angle to each other. Thus several flow velocities within the vessel and the vessel diameter can be measured. 77 healthy patients (41 women, 36 men) were included and divided into age groups of ten-year intervals (mean age 48.9 years). Internal carotid artery flow was evaluated as well as physiological and hematological parameters (hematocrit, arterial blood pressure etc).
FINDINGS: We found that the blood flow volume in the ICA decreased significantly with age. No side-to-side effects as well as no gender-related differences could be observed. There was no influence of hemoglobin, hematocrit and blood pressure in this healthy population.
CONCLUSIONS: There is an age-related decrease in blood flow volume with age that can be easily and exactly determined by the use of the new angle-independent Doppler technique.

Entities:  

Mesh:

Year:  2004        PMID: 15340809     DOI: 10.1007/s00701-004-0324-2

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  5 in total

Review 1.  The application of ultrasound in the management of cerebral arteriovenous malformation.

Authors:  Bing Fu; Ji-Zong Zhao; Lan-Bing Yu
Journal:  Neurosci Bull       Date:  2008-12       Impact factor: 5.203

2.  Laser speckle flowgraphy for differentiating between nonarteritic ischemic optic neuropathy and anterior optic neuritis.

Authors:  Tomoyuki Maekubo; Hideki Chuman; Nobuhisa Nao-I
Journal:  Jpn J Ophthalmol       Date:  2013-05-22       Impact factor: 2.447

3.  Carotid stenosis assessed with a 4-dimensional semiautomated Doppler system.

Authors:  Flemming Forsberg; Alan D Stein; Daniel A Merton; Kathryn J Lipcan; Donald Herzog; Laurence Parker; Laurence Needleman
Journal:  J Ultrasound Med       Date:  2008-09       Impact factor: 2.153

4.  Fabrication and in vitro deployment of a laser-activated shape memory polymer vascular stent.

Authors:  Géraldine M Baer; Ward Small; Thomas S Wilson; William J Benett; Dennis L Matthews; Jonathan Hartman; Duncan J Maitland
Journal:  Biomed Eng Online       Date:  2007-11-27       Impact factor: 2.819

5.  Volumetric Carotid Flow Characteristics in Doppler Ultrasonography in Healthy Population Over 65 Years Old.

Authors:  Piotr Kaszczewski; Michal Elwertowski; Jerzy Leszczynski; Tomasz Ostrowski; Zbigniew Galazka
Journal:  J Clin Med       Date:  2020-05-07       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.