The human ankle during walking: implications for design of biomimetic ankle prostheses.

Andrew H Hansen1, Dudley S Childress, Steve C Miff, Steven A Gard, Kent P Mesplay.   

Abstract

The non-disabled human ankle joint was examined during walking in an attempt to determine overall system characteristics for use in the design of ankle prostheses. The hypothesis of the study was that the quasi-stiffness of the ankle changes when walking at different walking speeds. The hypothesis was examined using sagittal plane ankle moment versus ankle angle curves from 24 able-bodied subjects walking over a range of speeds. The slopes of the moment versus ankle angle curves (quasi-stiffness) during loading appeared to change as speed was increased and the relationship between the moment and angle during loading became increasingly non-linear. The loading and unloading portions of the moment versus angle curves showed clockwise loops (hysteresis) at self-selected slow speeds that reduced essentially to zero as the speed increased to self-selected normal speeds. Above self-selected normal speeds, the loops started to traverse a counter-clockwise path that increased in area as the speed was increased. These characteristics imply that the human ankle joint could be effectively replaced with a rotational spring and damper for slow to normal walking speeds. However, to mimic the characteristics of the human ankle during walking at fast speeds, an augmented system would be necessary. This notion is supported by the sign of the ankle power at the time of opposite heel contact, which was negative for slow speeds, was near zero at normal speeds, and was positive for fast walking speeds.

Entities:  

Mesh:

Year:  2004        PMID: 15336920     DOI: 10.1016/j.jbiomech.2004.01.017

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  51 in total

1.  Mechanisms contributing to reduced knee stiffness during movement.

Authors:  Daniel Ludvig; Maciej Plocharski; Piotr Plocharski; Eric J Perreault
Journal:  Exp Brain Res       Date:  2017-07-15       Impact factor: 1.972

2.  Bionic ankle-foot prosthesis normalizes walking gait for persons with leg amputation.

Authors:  Hugh M Herr; Alena M Grabowski
Journal:  Proc Biol Sci       Date:  2011-07-13       Impact factor: 5.349

Review 3.  Dynamic principles of gait and their clinical implications.

Authors:  Arthur D Kuo; J Maxwell Donelan
Journal:  Phys Ther       Date:  2009-12-18

4.  An Untethered Ankle Exoskeleton Improves Walking Economy in a Pilot Study of Individuals With Cerebral Palsy.

Authors:  Zachary F Lerner; Gian Maria Gasparri; Michael O Bair; Jenny L Lawson; Jason Luque; Taryn A Harvey; Andrea T Lerner
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2018-09-17       Impact factor: 3.802

5.  Amputee Subject Testing Protocol, Results, and Analysis of a Powered Transtibial Prosthetic Device.

Authors:  Jinming Sun; Jessica M Fritz; David R Del Toro; Philip A Voglewede
Journal:  J Med Device       Date:  2014-08-19       Impact factor: 0.582

6.  Estimation of human ankle impedance during the stance phase of walking.

Authors:  Elliott J Rouse; Levi J Hargrove; Eric J Perreault; Todd A Kuiken
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2014-02-27       Impact factor: 3.802

7.  Human medial gastrocnemius force-velocity behavior shifts with locomotion speed and gait.

Authors:  Dominic James Farris; Gregory S Sawicki
Journal:  Proc Natl Acad Sci U S A       Date:  2012-01-04       Impact factor: 11.205

8.  System identification of physiological systems using short data segments.

Authors:  Daniel Ludvig; Eric J Perreault
Journal:  IEEE Trans Biomed Eng       Date:  2012-09-28       Impact factor: 4.538

9.  Informing Ankle-Foot Prosthesis Prescription through Haptic Emulation of Candidate Devices.

Authors:  Joshua M Caputo; Peter G Adamczyk; Steven H Collins
Journal:  IEEE Int Conf Robot Autom       Date:  2015-05

10.  Mechanical and energetic consequences of rolling foot shape in human walking.

Authors:  Peter G Adamczyk; Arthur D Kuo
Journal:  J Exp Biol       Date:  2013-04-11       Impact factor: 3.312

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.