Literature DB >> 15333478

Rates of glucose change measured by blood glucose meter and the GlucoWatch Biographer during day, night, and around mealtimes.

Timothy C Dunn1, Richard C Eastman, Janet A Tamada.   

Abstract

OBJECTIVE: The purpose of this study was to characterize the distribution of the rate of change of blood glucose for a diabetic population. RESEARCH DESIGN AND METHODS: The study population consisted of 124 adults with type 1 or type 2 diabetes requiring insulin. Study participants applied a GlucoWatch Biographer during the day at home for 5 consecutive days and took finger-prick blood glucose measurements hourly. Subjects kept a diary of meals. The Biographer frequently and automatically measured glucose up to three times per hour for up 12 h. Rates of glucose change were calculated for both Biographer and blood glucose measurements. Rates of glucose change during a separate study of 134 subjects were determined for daytime and nighttime use.
RESULTS: -Mean (+/-SD) rates of change of glucose of -0.36 +/- 0.95 and 0.36 +/- 0.99 mg. dl(-1). min(-1) were found before and after lunch using blood glucose data and -0.31 +/- 1.23 and 0.43 +/- 1.26 using Biographer data. For both types of diabetes, rates of glucose change exceeded 2 mg. dl(-1). min(-1) before and after meals approximately 10% of the time. Periprandial glucose patterns showed some significant differences between type 1 and type 2 diabetic subjects. Glucose levels changed more gradually at night than during the day.
CONCLUSIONS: Glucose values were almost equally unstable before and after meals. Glycemic instability around dinner was different in type 1 and type 2 diabetes. The GlucoWatch Biographer was found to be effective in tracking trends in glucose levels and yielded similar results as obtained by finger-prick blood samples.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15333478     DOI: 10.2337/diacare.27.9.2161

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  14 in total

Review 1.  Essential elements of the native glucoregulatory system, which, if appreciated, may help improve the function of glucose controllers in the intensive care unit setting.

Authors:  Leon DeJournett
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

2.  Numerical simulation of the effect of rate of change of glucose on measurement error of continuous glucose monitors.

Authors:  Marc B Taub; Thomas A Peyser; J Erik Rosenquist
Journal:  J Diabetes Sci Technol       Date:  2007-09

3.  Measurement of glucose in blood with a phenylboronic acid optical sensor.

Authors:  Graham J Worsley; Guilhem A Tourniaire; Kathryn E S Medlock; Felicity K Sartain; Hazel E Harmer; Michael Thatcher; Adrian M Horgan; John Pritchard
Journal:  J Diabetes Sci Technol       Date:  2008-03

4.  Magnetic nanosensors optimized for rapid and reversible self-assembly.

Authors:  Elisenda Rodriguez; Victor S Lelyveld; Tatjana Atanasijevic; Satoshi Okada; Alan Jasanoff
Journal:  Chem Commun (Camb)       Date:  2014-02-24       Impact factor: 6.222

5.  Selectivity assessment of noninvasive glucose measurements based on analysis of multivariate calibration vectors.

Authors:  Mark A Arnold; Lingzhi Liu; Jonathon T Olesberg
Journal:  J Diabetes Sci Technol       Date:  2007-07

6.  Design of the health monitoring system for the artificial pancreas: low glucose prediction module.

Authors:  Rebecca A Harvey; Eyal Dassau; Howard Zisser; Dale E Seborg; Lois Jovanovič; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

7.  For better and worse? The roles of closeness, marital behavior, and age in spouses' cardiometabolic similarity.

Authors:  Stephanie J Wilson; Juan Peng; Rebecca Andridge; Lisa M Jaremka; Christopher P Fagundes; William B Malarkey; Martha A Belury; Janice K Kiecolt-Glaser
Journal:  Psychoneuroendocrinology       Date:  2020-06-17       Impact factor: 4.905

8.  Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.

Authors:  Tai-Ping Sun; Hsiu-Li Shieh; Congo Tak-Shing Ching; Yan-Dong Yao; Su-Hua Huang; Chia-Ming Liu; Wei-Hao Liu; Chung-Yuan Chen
Journal:  Int J Nanomedicine       Date:  2010-05-13

9.  Establishing a continuous glucose monitoring program.

Authors:  Howard Wolpert
Journal:  J Diabetes Sci Technol       Date:  2008-03

10.  Preclinical in vivo study of a fluorescence affinity sensor for short-term continuous glucose monitoring in a small and large animal model.

Authors:  Ralph Dutt-Ballerstadt; Colton Evans; Ashok Gowda; Roger McNichols
Journal:  Diabetes Technol Ther       Date:  2008-12       Impact factor: 6.118

View more