Literature DB >> 15333426

Closed suctioning system reduces cross-contamination between bronchial system and gastric juices.

Werner Rabitsch1, Wolfgang J Köstler, Wolfgang Fiebiger, Christoph Dielacher, Heidrun Losert, Camillo Sherif, Thomas Staudinger, Edith Seper, Walter Koller, Florian Daxböck, Ernst Schuster, Paul Knöbl, Heinz Burgmann, Michael Frass.   

Abstract

In this prospective, randomized study, we evaluated whether a closed suctioning (CS) system (TrachCare) influences crossover contamination between bronchial system and gastric juices when compared with an open suctioning system (OS). The secondary aims were an analysis of the frequency of ventilator-associated pneumonia (VAP) and an analysis of alteration in gas exchange. Antibiograms were performed from tracheal secretions and gastric juice aspirates on Days 1 and 3 of intubation in 24 patients in a medical intensive care unit. Five cross-contaminations were observed in the OS group on Day 3 versus Day 1; the 5 strains shared common genotypes as determined by random amplification of polymorphic DNA. No cross-contaminations were seen in the CS group (P = 0.037). VAP occurred in 5 patients of the OS group but in none of the CS group patients (P = 0.037). Spao(2) decreased significantly in the OS group compared with presuctioning values--the opposite of the CS group. Whereas presuctioning values were comparable between groups, postsuctioning Spao(2) was significantly higher in the CS group. CS significantly reduced cross-contamination between bronchial system and gastric juices and reduced the incidence of VAP when compared with OS. Hypoxic phases can be reduced by the help of CS.

Entities:  

Mesh:

Year:  2004        PMID: 15333426     DOI: 10.1213/01.ANE.0000143353.85428.39

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  16 in total

1.  Endotracheal suctioning, ventilator-associated pneumonia, and costs: open or closed issue?

Authors:  Salvatore Maurizio Maggiore
Journal:  Intensive Care Med       Date:  2006-03-02       Impact factor: 17.440

Review 2.  Updating the evidence-base for suctioning adult patients: a systematic review.

Authors:  Tom J Overend; Cathy M Anderson; Dina Brooks; Lisa Cicutto; Michael Keim; Debra McAuslan; Mika Nonoyama
Journal:  Can Respir J       Date:  2009 May-Jun       Impact factor: 2.409

3.  Impact of the suctioning system (open vs. closed) on the incidence of ventilation-associated pneumonia: Meta-analysis of randomized controlled trials.

Authors:  Ralf-Peter Vonberg; Tim Eckmanns; Tobias Welte; Petra Gastmeier
Journal:  Intensive Care Med       Date:  2006-06-21       Impact factor: 17.440

Review 4.  Impact of closed versus open tracheal suctioning systems for mechanically ventilated adults: a systematic review and meta-analysis.

Authors:  Akira Kuriyama; Noriyuki Umakoshi; Jun Fujinaga; Tadaaki Takada
Journal:  Intensive Care Med       Date:  2014-11-26       Impact factor: 17.440

5.  Experimental contamination of a closed endotracheal suction system: 24 h vs 72 h.

Authors:  E Meyer; M Schuhmacher; W Ebner; M Dettenkofer
Journal:  Infection       Date:  2008-10-30       Impact factor: 3.553

6.  Case fatality rate related to nosocomial and ventilator-associated pneumonia in an ICU: a single-centre retrospective cohort study.

Authors:  Murat Yalçınsoy; Cuneyt Salturk; Hurıye Berk Takır; Semra Batı Kutlu; Ayşegul Oguz; Emine Aksoy; Merih Balcı; Feyza Kargın; Ozlem Yazıcıoglu Mocin; Nalan Adıguzel; Gokay Gungor; Zuhal Karakurt
Journal:  Wien Klin Wochenschr       Date:  2015-11-05       Impact factor: 1.704

7.  Comparing influence of intermittent subglottic secretions drainage with/without closed suction systems on the incidence of ventilator associated pneumonia.

Authors:  Deven Juneja; Yash Javeri; Omender Singh; Prashant Nasa; Rameshwar Pandey; Bhupesh Uniyal
Journal:  Indian J Crit Care Med       Date:  2011-07

Review 8.  Paradoxical ventilator associated pneumonia incidences among selective digestive decontamination studies versus other studies of mechanically ventilated patients: benchmarking the evidence base.

Authors:  James C Hurley
Journal:  Crit Care       Date:  2011-01-07       Impact factor: 9.097

9.  Fractured closed suction catheter: an unusual cause of endobronchial obstruction in a ventilated patient.

Authors:  M P Rogan; B Marsh
Journal:  Ir J Med Sci       Date:  2008-09-24       Impact factor: 1.568

10.  Comparing two levels of closed system suction pressure in ICU patients: Evaluating the relative safety of higher values of suction pressure.

Authors:  Ahmad R Yazdannik; Somayeh Haghighat; Mahmoud Saghaei; Maryam Eghbali
Journal:  Iran J Nurs Midwifery Res       Date:  2013-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.