A comparison of the failure times of pulse oximeters during blood pressure cuff-induced hypoperfusion in volunteers.

Toshiya Kawagishi1, Noriaki Kanaya, Masayasu Nakayama, Saori Kurosawa, Akiyoshi Namiki.   

Abstract

Important information may not be obtained if the pulse oximetry signal is lost during inflation of a cuff for blood pressure measurement, particularly in patients with hemodynamic instability. In the present study, we compared the failure times of pulse oximeters during cuff-induced hypoperfusion in volunteers. A pulse oximeter sensor was attached to the index finger, and a blood pressure cuff was attached to the same arm of each volunteer. MasimoSET Radical (Masimo), Nellcor N-395 (N-395), Nellcor N-20PA, and Nellcor D-25 were tested. To evaluate the failure time of each pulse oximeter, time to peak of cuff pressure, time to loss of signal, time to recovery of signal, and failure interval were measured. All measurements were performed three times for each pulse oximeter and were averaged. There were no differences in hemodynamic measurements among the groups. Time to loss of signal was longer in Masimo than the other pulse oximeters. Masimo and N-395 showed significantly shorter times to recovery of signal than those of the other two pulse oximeters. Failure interval was in the order of Masimo << N-395 < Nellcor D-25 = Nellcor N-20PA. Masimo did not lose a signal as rapidly as the other oximeters studied. Masimo was similar in performance to the N-395 at providing useful data sooner than conventional technology after a loss of the signal. These observations suggest that data will be more available with fewer false-positive alarms when using the Masimo oximeter followed by the N-395 when compared with conventional oximeters.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15333413     DOI: 10.1213/01.ANE.0000130343.66453.37

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

1.  The Importance of State and Context in Safe Interoperable Medical Systems.

Authors:  Sandy Weininger; Michael B Jaffe; Michael Robkin; Tracy Rausch; David Arney; Julian M Goldman
Journal:  IEEE J Transl Eng Health Med       Date:  2016-08-08       Impact factor: 3.316

2.  Evaluation of finger and forehead pulse oximeters during mild hypothermic cardiopulmonary bypass.

Authors:  Ken Yamaura; Kazuo Irita; Tadashi Kandabashi; Kohei Tohyama; Shosuke Takahashi
Journal:  J Clin Monit Comput       Date:  2007-06-20       Impact factor: 1.977

3.  Prevention of retinopathy of prematurity in preterm infants through changes in clinical practice and SpO₂technology.

Authors:  Armando Castillo; Richard Deulofeut; Ann Critz; Augusto Sola
Journal:  Acta Paediatr       Date:  2010-10-15       Impact factor: 2.299

Review 4.  Safe oxygen saturation targeting and monitoring in preterm infants: can we avoid hypoxia and hyperoxia?

Authors:  Augusto Sola; Sergio G Golombek; María Teresa Montes Bueno; Lourdes Lemus-Varela; Claudia Zuluaga; Fernando Domínguez; Hernando Baquero; Alejandro E Young Sarmiento; Diego Natta; Jose M Rodriguez Perez; Richard Deulofeut; Ana Quiroga; Gabriel Lara Flores; Mónica Morgues; Alfredo García-Alix Pérez; Bart Van Overmeire; Frank van Bel
Journal:  Acta Paediatr       Date:  2014-07-28       Impact factor: 2.299

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.