Literature DB >> 15333374

Low-dose chest CT: optimizing radiation protection for patients.

Xiaohua Zhu1, Jianqun Yu, Zheng Huang.   

Abstract

OBJECTIVE: The aim of our study was to evaluate CT scanning protocols to determine how best to minimize patient exposure to ionizing radiation while maintaining sufficient image quality to detect pulmonary diseases. SUBJECT AND METHODS: The CT dose index (CTDI) was determined by scanning an acrylic phantom at various tube current-time products (7.5-115 mAs). Image quality was evaluated by comparing the homogeneity and noise level of CT scans obtained in the acrylic phantom with those obtained in a water-equivalent phantom. The CT scans obtained at various milliampere-second settings in patients with nodules or diffuse opacifications were assessed. The relationships between the CTDI and the image quality of the CT scans (noise level and artifacts) were established.
RESULTS: The reduction of a conventional tube current-time product (115 mAs) by 65%, 78%, or 93.5% can decrease the CTDI by 60%, 70%, or 85%, respectively. In correlating the image quality of each CT scan to the milliampere-second settings used to obtain it, we found that homogeneity decreased as milliampere-second settings decreased, whereas the noise level increased as milliampere-second settings decreased. For both 8- and 3-mm slice thicknesses, the homogeneity of CT scans acquired at 7.5 mAs or greater was within the acceptable range (< 4 H). However, the noise level of CT scans remained within the acceptable range (< 0.35%) when 25 mAs or greater was used. The evaluation of the image quality of the patients' CT scans indicated no statistical significance in image quality rating between the scans obtained at 25 mAs and those obtained at 115 mAs (p > 0.01).
CONCLUSION: Low-dose (i.e., 40 or 25 mAs) helical chest CT produced satisfactory image quality and reduced the CTDI, thereby maximally protecting patients from radiation exposure.

Entities:  

Mesh:

Year:  2004        PMID: 15333374     DOI: 10.2214/ajr.183.3.1830809

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  22 in total

1.  The National Lung Screening Trial: overview and study design.

Authors:  Denise R Aberle; Christine D Berg; William C Black; Timothy R Church; Richard M Fagerstrom; Barbara Galen; Ilana F Gareen; Constantine Gatsonis; Jonathan Goldin; John K Gohagan; Bruce Hillman; Carl Jaffe; Barnett S Kramer; David Lynch; Pamela M Marcus; Mitchell Schnall; Daniel C Sullivan; Dorothy Sullivan; Carl J Zylak
Journal:  Radiology       Date:  2010-11-02       Impact factor: 11.105

2.  Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography.

Authors:  Emilio Quaia; Elisa Baratella; Stefano Cernic; Arianna Lorusso; Federica Casagrande; Vincenzo Cioffi; Maria Assunta Cova
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

3.  Dose estimation of ultra-low-dose chest CT to different sized adult patients.

Authors:  Tony M Svahn; Tommy Sjöberg; Jennifer C Ast
Journal:  Eur Radiol       Date:  2018-12-17       Impact factor: 5.315

4.  Can a revised paediatric radiation dose reduction CT protocol be applied and still maintain anatomical delineation, diagnostic confidence and overall imaging quality?

Authors:  S Kritsaneepaiboon; P Siriwanarangsun; P Tanaanantarak; A Krisanachinda
Journal:  Br J Radiol       Date:  2014-06-24       Impact factor: 3.039

5.  Evaluation of chest CT scan in low-weight children with ultralow tube voltage (70 kVp) combined with Flash scan technique.

Authors:  Jiang W Shi; Dong F Xu; Hong Z Dai; Li Shen; Yi D Ji
Journal:  Br J Radiol       Date:  2016-01-19       Impact factor: 3.039

6.  Diagnostic impact of digital tomosynthesis in oncologic patients with suspected pulmonary lesions on chest radiography.

Authors:  Emilio Quaia; Elisa Baratella; Gabriele Poillucci; Antonio Giulio Gennari; Maria Assunta Cova
Journal:  Eur Radiol       Date:  2015-12-01       Impact factor: 5.315

7.  Ultra-low-dose MDCT of the chest: influence on automated lung nodule detection.

Authors:  Ji Young Lee; Myung Jin Chung; Chin A Yi; Kyung Soo Lee
Journal:  Korean J Radiol       Date:  2008 Mar-Apr       Impact factor: 3.500

8.  Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner.

Authors:  Roshan S Livingstone; Joe Pradip; Paul M Dinakran; B Srikanth
Journal:  Indian J Radiol Imaging       Date:  2010-05

Review 9.  The radiation burden of radiological investigations.

Authors:  W Mazrani; K McHugh; P J Marsden
Journal:  Arch Dis Child       Date:  2007-12       Impact factor: 3.791

10.  Is weight-based adjustment of automatic exposure control necessary for the reduction of chest CT radiation dose?

Authors:  Priyanka Prakash; Mannudeep K Kalra; Matthew D Gilman; Jo-Anne O Shepard; Subba R Digumarthy
Journal:  Korean J Radiol       Date:  2009-12-28       Impact factor: 3.500