Literature DB >> 15333342

MRI-guided radiofrequency thermal ablation of normal lung tissue: in vivo study in a rabbit model.

Frank K Wacker1, Sherif G Nour, Rosana Eisenberg, Jeffrey L Duerk, Jonathan S Lewin.   

Abstract

OBJECTIVE: The purpose of this study was to assess the feasibility of MRI to guide and monitor radiofrequency ablation of normal pulmonary tissue in a rabbit model.
MATERIALS AND METHODS: Percutaneous puncture and lung radiofrequency ablation were performed in six New Zealand white rabbits under MRI control using a 0.2-T open MRI scanner. Technical feasibility and complication detection were evaluated. The ablation zone appearance and size were assessed using MRI, CT, and gross pathology. Interclass correlation coefficients (ICCs) of the maximum short-axis diameters of the lesions on gross pathology and the corresponding diameters as measured on each MRI pulse sequence and on CT scans were calculated.
RESULTS: MRI guidance of percutaneous puncture and radiofrequency ablation of pulmonary tissue is feasible. A pneumothorax was detected and treated using MRI. In the specimen, the mean coagulation necrosis diameter was 9.8 mm. The T1-weighted spoiled gradient-echo fast low-angle shot images showed the highest ICC (0.81) for the thermal lesion diameter.
CONCLUSION: Our results indicate that MRI guidance is feasible and useful for radiofrequency ablation of normal pulmonary tissue.

Entities:  

Mesh:

Year:  2004        PMID: 15333342     DOI: 10.2214/ajr.183.3.1830599

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Ultrasound simulation of real-time temperature estimation during radiofrequency ablation using finite element models.

Authors:  M J Daniels; J Jiang; T Varghese
Journal:  Ultrasonics       Date:  2007-11-05       Impact factor: 2.890

2.  Influence of endourological devices on 3D reconstruction image quality using the Uro Dyna-CT.

Authors:  M-C Rassweiler; M Ritter; M-S Michel; A Häcker
Journal:  World J Urol       Date:  2012-08-03       Impact factor: 4.226

3.  [New puncture techniques in urology using 3D-assisted imaging].

Authors:  M Ritter; M-C Rassweiler; J J Rassweiler; M S Michel
Journal:  Urologe A       Date:  2012-12       Impact factor: 0.639

4.  Projection-based visual guidance for robot-aided RF needle insertion.

Authors:  Rong Wen; Chee-Kong Chui; Sim-Heng Ong; Kah-Bin Lim; Stephen Kin-Yong Chang
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-05-07       Impact factor: 2.924

5.  Ultrasound-based relative elastic modulus imaging for visualizing thermal ablation zones in a porcine model.

Authors:  Jingfeng Jiang; Chris Brace; Anita Andreano; Ryan J DeWall; Nick Rubert; Ted G Fisher; Tomy Varghese; Fred Lee; Timothy J Hall
Journal:  Phys Med Biol       Date:  2010-03-30       Impact factor: 3.609

Review 6.  CT-guided radiofrequency ablation for lung cancer.

Authors:  Toshiyuki Matsuoka; Tomohisa Okuma
Journal:  Int J Clin Oncol       Date:  2007-04-27       Impact factor: 3.402

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.