Literature DB >> 15330775

Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance.

L Fang1, D P Wyon, G Clausen, P O Fanger.   

Abstract

UNLABELLED: Perceived air quality (PAQ), sick building syndrome (SBS) symptoms and performance of office work were studied in a real office space at three levels of air temperature and humidity and two levels of ventilation rate (20 degrees C/40%, 23 degrees C/50%, 26 degrees C/60% RH at 10 l s(-1) p(-1) outside air, and 20 degrees C/40% RH at 3.5 l s(-1) p(-1) outside air). Thirty female subjects participated in the experiment. They were exposed to each environmental condition for 280 min. Thermal comfort was maintained at different thermal environments by self-adjustment of clothing. The subjects performed simulated office work throughout each exposure and repeatedly marked a set of visual-analog scales to indicate their perception of environmental conditions and of the intensity of SBS symptoms at the time. The study confirmed the previously observed impact of temperature and humidity on perceived air quality and the linear correlation between acceptability and enthalpy. The impact on perceived air quality of decreasing the ventilation rate from 10 to 3.5 l s(-1) per person could be counteracted by a decrement of temperature and humidity from 23 degrees C/50% RH to 20 degrees C/40% RH. Performance of office work was not significantly affected by indoor air temperature and humidity. However, several SBS symptoms were alleviated when the subjects worked at low levels of air temperature and humidity, which implies that a longer term exposure to low indoor air temperature and humidity might help to improve the performance of office work. PRACTICAL IMPLICATIONS: The findings of this study indicate the importance of indoor air temperature and humidity on perceived air quality and SBS symptoms. In practice, the required ventilation rate for comfort and health should no longer be independent of indoor air temperature and humidity.

Entities:  

Mesh:

Year:  2004        PMID: 15330775     DOI: 10.1111/j.1600-0668.2004.00276.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  15 in total

1.  Changes in EEG signals during the cognitive activity at varying air temperature and relative humidity.

Authors:  Minghui Zhu; Weiwei Liu; Pawel Wargocki
Journal:  J Expo Sci Environ Epidemiol       Date:  2019-06-24       Impact factor: 5.563

2.  Carbon dioxide (CO2) demand-controlled ventilation in university computer classrooms and possible effects on headache, fatigue and perceived indoor environment: an intervention study.

Authors:  Dan Norbäck; Klas Nordström; Zhuohui Zhao
Journal:  Int Arch Occup Environ Health       Date:  2012-03-16       Impact factor: 3.015

3.  The office experiment: Can science build the perfect workspace?

Authors:  Emily Anthes
Journal:  Nature       Date:  2016-09-15       Impact factor: 49.962

4.  Urban daily life routines and human exposure to environmental discomfort.

Authors:  I Schnell; O Potchter; Y Yaakov; Y Epstein; S Brener; H Hermesh
Journal:  Environ Monit Assess       Date:  2011-08-09       Impact factor: 2.513

5.  Vocal function and upper airway thermoregulation in five different environmental conditions.

Authors:  Mary J Sandage; Nadine P Connor; David D Pascoe
Journal:  J Speech Lang Hear Res       Date:  2014-02       Impact factor: 2.297

6.  Headache symptoms and indoor environmental parameters: Results from the EPA BASE study.

Authors:  Gretchen E Tietjen; Jagdish Khubchandani; Somik Ghosh; Suchismita Bhattacharjee; Joann Kleinfelder
Journal:  Ann Indian Acad Neurol       Date:  2012-08       Impact factor: 1.383

7.  Effect of aerosol particles generated by ultrasonic humidifiers on the lung in mouse.

Authors:  Masakazu Umezawa; Keisuke Sekita; Ken-Ichiro Suzuki; Miyoko Kubo-Irie; Rikio Niki; Tomomi Ihara; Masao Sugamata; Ken Takeda
Journal:  Part Fibre Toxicol       Date:  2013-12-21       Impact factor: 9.400

8.  School environment as predictor of teacher sick leave: data-linked prospective cohort study.

Authors:  Jenni Ervasti; Mika Kivimäki; Ichiro Kawachi; S V Subramanian; Jaana Pentti; Tuula Oksanen; Riikka Puusniekka; Tiina Pohjonen; Jussi Vahtera; Marianna Virtanen
Journal:  BMC Public Health       Date:  2012-09-11       Impact factor: 3.295

9.  Gender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia.

Authors:  Aizat Ismail Syazwan; Juahir Hafizan; Mohd Rafee Baharudin; Ahmad Zaid Fattah Azman; Zulkapri Izwyn; Ismail Zulfadhli; Katis Syahidatussyakirah
Journal:  Ther Clin Risk Manag       Date:  2013-03-08       Impact factor: 2.423

10.  Associations between Parents' Perceived Air Quality in Homes and Health among Children in Nanjing, China.

Authors:  Hua Qian; Xiaohong Zheng; Min Zhang; Louise Weschler; Jan Sundell
Journal:  PLoS One       Date:  2016-05-18       Impact factor: 3.240

View more