PURPOSE: To study the short-term reproducibility of lung density measurements by multi-slice computed tomography (CT) using three different radiation doses and three reconstruction algorithms. MATERIAL AND METHODS: Twenty-five patients with smoker's emphysema and 25 patients with alpha1-antitrypsin deficiency underwent 3 scans at 2-week intervals. Low-dose protocol was applied, and images were reconstructed with bone, detail, and soft algorithms. Total lung volume (TLV), 15th percentile density (PD-15), and relative area at -910 Hounsfield units (RA-910) were obtained from the images using Pulmo-CMS software. Reproducibility of PD-15 and RA-910 and the influence of radiation dose, reconstruction algorithm, and type of emphysema were then analysed. RESULTS: The overall coefficient of variation of volume adjusted PD-15 for all combinations of radiation dose and reconstruction algorithm was 3.7%. The overall standard deviation of volume-adjusted RA-910 was 1.7% (corresponding to a coefficient of variation of 6.8%). Radiation dose, reconstruction algorithm, and type of emphysema had no significant influence on the reproducibility of PD-15 and RA-910. However, bone algorithm and very low radiation dose result in overestimation of the extent of emphysema. CONCLUSION: Lung density measurement by CT is a sensitive marker for quantitating both subtypes of emphysema. A CT-protocol with radiation dose down to 16 mAs and soft or detail reconstruction algorithm is recommended.
PURPOSE: To study the short-term reproducibility of lung density measurements by multi-slice computed tomography (CT) using three different radiation doses and three reconstruction algorithms. MATERIAL AND METHODS: Twenty-five patients with smoker's emphysema and 25 patients with alpha1-antitrypsindeficiency underwent 3 scans at 2-week intervals. Low-dose protocol was applied, and images were reconstructed with bone, detail, and soft algorithms. Total lung volume (TLV), 15th percentile density (PD-15), and relative area at -910 Hounsfield units (RA-910) were obtained from the images using Pulmo-CMS software. Reproducibility of PD-15 and RA-910 and the influence of radiation dose, reconstruction algorithm, and type of emphysema were then analysed. RESULTS: The overall coefficient of variation of volume adjusted PD-15 for all combinations of radiation dose and reconstruction algorithm was 3.7%. The overall standard deviation of volume-adjusted RA-910 was 1.7% (corresponding to a coefficient of variation of 6.8%). Radiation dose, reconstruction algorithm, and type of emphysema had no significant influence on the reproducibility of PD-15 and RA-910. However, bone algorithm and very low radiation dose result in overestimation of the extent of emphysema. CONCLUSION: Lung density measurement by CT is a sensitive marker for quantitating both subtypes of emphysema. A CT-protocol with radiation dose down to 16 mAs and soft or detail reconstruction algorithm is recommended.
Authors: Miranda Kirby; Charles Hatt; Nancy Obuchowski; Stephen M Humphries; Jered Sieren; David A Lynch; Sean B Fain Journal: Med Phys Date: 2020-03-31 Impact factor: 4.071
Authors: Wassim W Labaki; Carlos H Martinez; Fernando J Martinez; Craig J Galbán; Brian D Ross; George R Washko; R Graham Barr; Elizabeth A Regan; Harvey O Coxson; Eric A Hoffman; John D Newell; Douglas Curran-Everett; James C Hogg; James D Crapo; David A Lynch; Ella A Kazerooni; MeiLan K Han Journal: Am J Respir Crit Care Med Date: 2017-12-01 Impact factor: 21.405
Authors: Barbaros Selnur Erdal; Elliott D Crouser; Vedat Yildiz; Mark A King; Andrew T Patterson; Michael V Knopp; Bradley D Clymer Journal: Chest Date: 2012-12 Impact factor: 9.410
Authors: Sushravya Raghunath; Srinivasan Rajagopalan; Ronald A Karwoski; Brian J Bartholmai; Richard A Robb Journal: J Digit Imaging Date: 2014-08 Impact factor: 4.056
Authors: Laura H Thomsen; Saher B Shaker; Asger Dirksen; Jesper H Pedersen; Ruth Tal-Singer; Per Bakke; Jørgen Vestbo Journal: Chronic Obstr Pulm Dis Date: 2015-05-19
Authors: Andreas W Reske; Harald Busse; Marcelo B P Amato; Matthias Jaekel; Thomas Kahn; Peter Schwarzkopf; Dierk Schreiter; Udo Gottschaldt; Matthias Seiwerts Journal: Intensive Care Med Date: 2008-06-08 Impact factor: 17.440