Literature DB >> 15316474

Plasma arc versus halogen light-curing of adhesive-precoated orthodontic brackets: a 12-month clinical study of bond failures.

Vittorio Cacciafesta1, Maria Francesca Sfondrini, Andrea Scribante.   

Abstract

The purpose of this randomized clinical trial was to evaluate the performance of adhesive-precoated brackets cured with 2 different light-curing units (conventional halogen light and plasma arc light). Thirty patients treated with fixed appliances were included in the investigation. Each patient's mouth was divided by the split-mouth design into 4 quadrants. In 15 randomly selected patients, the maxillary left and mandibular right quadrants were cured with the halogen light, and the remaining quadrants were cured with the plasma arc light. In the other 15 patients, the quadrants were inverted. A total of 600 adhesive precoated stainless steel brackets were examined: 300 were cured with a conventional halogen light for 20 seconds, and the others were cured with the plasma arc light for 5 seconds. The number, cause, and date of bracket failures were recorded for each light-curing unit over 12 months. Statistical analysis was performed with the Fisher exact test, Kaplan-Meier survival estimates, and the log-rank test. No statistically significant differences in bond failure rates were found between the adhesive-precoated brackets cured with the halogen light and those cured with the plasma arc light; neither were any significant differences in performance found with each light-curing unit between the maxillary and mandibular arches. Plasma arc lights can be considered an advantageous alternative to conventional light curing, because they enable the clinician to reduce the curing time of adhesive-precoated orthodontic brackets without significantly affecting their bond failure rate.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15316474     DOI: 10.1016/j.ajodo.2003.05.004

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

1.  Clinical effect of reducing curing times with high-intensity LED lights.

Authors:  Justin D Ward; Bethany J Wolf; Luis P Leite; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

2.  Computerized Casts for Orthodontic Purpose Using Powder-Free Intraoral Scanners: Accuracy, Execution Time, and Patient Feedback.

Authors:  Maria Francesca Sfondrini; Paola Gandini; Maurizio Malfatto; Francesco Di Corato; Federico Trovati; Andrea Scribante
Journal:  Biomed Res Int       Date:  2018-04-23       Impact factor: 3.411

3.  Evaluation of Bond Failure Rate of Orthodontic Brackets Bonded with Green Gloo-Two Way Color Changes Adhesive: A Clinical Study.

Authors:  Zuber Ahamed Naqvi; Saleem Shaikh; Zameer Pasha
Journal:  Ethiop J Health Sci       Date:  2019-03
  3 in total