Literature DB >> 15309408

Computed tomography determined femoral torsion is not accurate.

R L Jaarsma1, A W A Bruggeman, D F M Pakvis, N Verdonschot, J A M Lemmens, A van Kampen.   

Abstract

INTRODUCTION: Computed tomography (CT) is considered the method of choice for detecting rotational malalignment of the femur. However, it is unclear how reliable the method is, and what the causes are of potential inaccuracies.
MATERIALS AND METHODS: To address these issues three observers measured the CT images of the femur of 76 patients on two separate occasions. The images were made during follow-up of a unilateral femoral shaft fractures. Rotational malalignment was determined by comparing the torsion angle of the injured to the noninjured leg.
RESULTS: The pooled intraobserver variance was 3.9 degrees and interobserver variance 4.1 degrees. Of the two measurements of one observer 95% were up to 10.8 degrees different, and between observers 95% of the measurements were up to 15.6 degrees different.
CONCLUSIONS: CT measurements of rotational malalignment of the femur are not accurate. This is due principally to the difficulty in defining a line through the axis of the femoral neck. The accuracy can be improved by taking the average of two measurements.

Entities:  

Mesh:

Year:  2004        PMID: 15309408     DOI: 10.1007/s00402-004-0729-7

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  8 in total

1.  Aberrant femoral torsion presenting with frog-leg squatting mimicking gluteal muscle contracture.

Authors:  Chia-Ling Chiang; Meng-Yuan Tsai; Wei-Ning Chang; Clement Kuen-Huang Chen
Journal:  Clin Orthop Relat Res       Date:  2011-09-20       Impact factor: 4.176

2.  Reliability of the assessment of lower limb torsion using computed tomography: analysis of five different techniques.

Authors:  Emmanouil Liodakis; Iosifina Doxastaki; Kongfai Chu; Christian Krettek; Ralph Gaulke; Musa Citak; Mohamed Kenawey
Journal:  Skeletal Radiol       Date:  2011-05-11       Impact factor: 2.199

3.  Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients.

Authors:  Kasper W Janssen; Jan Biert; Albert van Kampen
Journal:  Int Orthop       Date:  2006-12-12       Impact factor: 3.075

4.  The association between idiopathic clubfoot and increased internal hip rotation.

Authors:  John P Howlett; Vincent S Mosca; Kristie Bjornson
Journal:  Clin Orthop Relat Res       Date:  2009-02-20       Impact factor: 4.176

5.  Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study.

Authors:  Artemisia Panou; Dedorah Faith Stanitski; Carl Stanitski; Andrea Peccati; Nicola Marcello Portinaro
Journal:  J Orthop Surg Res       Date:  2015-05-15       Impact factor: 2.359

6.  Application of three-dimensional reconstruction to improve the preoperative measurement accuracy and applicability of femoral neck torsion angle.

Authors:  Qing Han; Aobo Zhang; Chenyu Wang; Kerong Yang; Jincheng Wang
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

7.  Artificial intelligence-based automatic assessment of lower limb torsion on MRI.

Authors:  Justus Schock; Daniel Truhn; Darius Nürnberger; Stefan Conrad; Marc Sebastian Huppertz; Sebastian Keil; Christiane Kuhl; Dorit Merhof; Sven Nebelung
Journal:  Sci Rep       Date:  2021-12-01       Impact factor: 4.379

8.  Impact of specialty and level of training on CT measurement of femoral version: an interobserver agreement analysis.

Authors:  Richard S Yoon; John D Koerner; Neeraj M Patel; Michael S Sirkin; Mark C Reilly; Frank A Liporace
Journal:  J Orthop Traumatol       Date:  2013-08-29
  8 in total