Literature DB >> 15308241

Continuous flow immunosensor for highly selective and real-time detection of sub-ppb levels of 2-hydroxybiphenyl by using surface plasmon resonance imaging.

K Vengatajalabathy Gobi1, Hiroyuki Tanaka, Yukihiro Shoyama, Norio Miura.   

Abstract

A biosensor based on surface plasmon resonance (SPR) is developed for the detection of 2-hydroxybiphenyl (HBP). A monoclonal antibody against HBP (abbreviated hereafter as HBP-mAb) is developed and used for the detection of HBP by competitive SPR-based immunoassay and enzyme linked immunosorbent assay (ELISA) methods. A novel HBP-hapten compound, HBP-bovine serum albumin conjugate (HBP-BSA), derived by binding several HBP units with BSA by an aliphatic chain spacer is used in the development of antibody and for the functionalization of immunoprobes. HBP-BSA linked to the Au surface of the SPR sensor chip undergoes inhibitive immunoreaction with HBP-mAb in the presence of free HBP. The SPR-based immunoassay provides a rapid determination (response time: approximately 20 min) of the concentration of HBP in the range of 0.1-1000 ppb (ng/ml). Regeneration of the sensor chip is gained by treating the antibody-anchored SPR sensor chip with a pepsin solution (100 ppm (microg/ml); pH 2.0) for few minutes. The SPR sensor chip is reusable for the detection of HBP for more than 20 cycles with average loss of 0.35% reactivity per regeneration step. HBP concentration is determined as low as 0.1 and 3 ppb using the SPR sensor and ELISA measurements, respectively. The developed SPR sensor for HBP is free from interference by coexisting benzo[a]pyrene (BaP), 2,4-dichlorophenoxyacetic acid (2,4-D) and benz[a]anthracene; SPR angle shift obtained to the flow of HBP is almost same irrespective to the presence or absence of a same concentration of these carcinogenic polycyclic aromatic hydrocarbons together. The SPR sensor for HBP is proved to be applicable in simultaneous detection of HBP and BaP in parallel with another SPR sensor for BaP.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15308241     DOI: 10.1016/j.bios.2004.02.003

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Concentration gradient immunoassay. 2. Computational modeling for analysis and optimization.

Authors:  Jennifer O Foley; Kjell E Nelson; Afshin Mashadi-Hossein; Bruce A Finlayson; Paul Yager
Journal:  Anal Chem       Date:  2007-04-17       Impact factor: 6.986

2.  Enhancing Surface Plasmon Resonance Detection Using Nanostructured Au Chips.

Authors:  Ivan Indutnyi; Yuriy Ushenin; Dirk Hegemann; Marianne Vandenbossche; Victor Myn'ko; Mariia Lukaniuk; Petro Shepeliavyi; Andrii Korchovyi; Roman Khrystosenko
Journal:  Nanoscale Res Lett       Date:  2016-12-01       Impact factor: 4.703

Review 3.  Surface plasmon resonance based biosensor: A new platform for rapid diagnosis of livestock diseases.

Authors:  Pravas Ranjan Sahoo; Parthasarathi Swain; Sudhanshu Mohan Nayak; Sudam Bag; Smruti Ranjan Mishra
Journal:  Vet World       Date:  2016-12-01

4.  Far- and deep-ultraviolet surface plasmon resonance sensors working in aqueous solutions using aluminum thin films.

Authors:  Ichiro Tanabe; Yoshito Y Tanaka; Koji Watari; Taras Hanulia; Takeyoshi Goto; Wataru Inami; Yoshimasa Kawata; Yukihiro Ozaki
Journal:  Sci Rep       Date:  2017-07-19       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.