Literature DB >> 15305448

The cone-beam algorithm of Feldkamp, Davis, and Kress preserves oblique line integrals.

Thomas Rodet1, Frédéric Noo, Michel Defrise.   

Abstract

The algorithm of Feldkamp, Davis, and Kress [J. Opt. Soc. Am. A 1, 612-619 (1984)] is a widely used filtered-backprojection algorithm for three-dimensional image reconstruction from cone-beam (CB) projections measured with a circular orbit of the x-ray source. A well-known property of this approximate algorithm is that the integral of the reconstructed image along any axial line orthogonal to the plane of the orbit is exact when the cone-beam projections are not truncated. We generalize this result to oblique line integrals, thus providing an efficient method to compute synthetic radiographs from cone-beam projections. Our generalized result is obtained by showing that the FDK algorithm is invariant under transformations that map oblique lines onto axial lines.

Mesh:

Year:  2004        PMID: 15305448     DOI: 10.1118/1.1759828

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Generation of voxelized breast phantoms from surgical mastectomy specimens.

Authors:  J Michael O'Connor; Mini Das; Clay S Dider; Mufeed Mahd; Stephen J Glick
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

2.  Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory.

Authors:  Stefan Hoppe; Joachim Hornegger; Frank Dennerlein; Günter Lauritsch; Frédéric Noo
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-05-21       Impact factor: 2.924

Review 3.  Maturation stage enamel malformations in Amtn and Klk4 null mice.

Authors:  Stephanie M Núñez; Yong-Hee P Chun; Bernhard Ganss; Yuanyuan Hu; Amelia S Richardson; James E Schmitz; Roberto Fajardo; Jie Yang; Jan C-C Hu; James P Simmer
Journal:  Matrix Biol       Date:  2015-11-24       Impact factor: 11.583

4.  In vivo accurate detection of the liver tumor with pharmacokinetic parametric images from dynamic fluorescence molecular tomography.

Authors:  Fei Liu; Peng Zhang; Zeyu Liu; Fan Song; Chenbin Ma; Yangyang Sun; Youdan Feng; Yufang He; Guanglei Zhang
Journal:  J Biomed Opt       Date:  2022-07       Impact factor: 3.758

5.  Fast reconstruction of 3D volumes from 2D CT projection data with GPUs.

Authors:  Miriam Leeser; Saoni Mukherjee; James Brock
Journal:  BMC Res Notes       Date:  2014-08-30

6.  Influence of Head Motion on the Accuracy of 3D Reconstruction with Cone-Beam CT: Landmark Identification Errors in Maxillofacial Surface Model.

Authors:  Kyung-Min Lee; Jin-Myoung Song; Jin-Hyoung Cho; Hyeon-Shik Hwang
Journal:  PLoS One       Date:  2016-04-11       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.