Literature DB >> 15304277

In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion.

Tetsu Watanabe1, Takaharu Yamazaki, Kazuomi Sugamoto, Tetsuya Tomita, Hideo Hashimoto, Daisuke Maeda, Shinichi Tamura, Takahiro Ochi, Hideki Yoshikawa.   

Abstract

The current study aimed to analyze kinematics during deep knee bending motion by subjects with fully congruent mobile-bearing total knee arthroplasties allowing axial rotation and anteroposterior (AP) gliding. Twelve subjects were implanted with Dual Bearing Knee prostheses (DBK, slot type: Finsbury Orthopaedics, Surrey, UK). These implants include a mobile-bearing insert that is fully congruent with the femoral component throughout flexion and allows axial rotation and limited AP translation. Sequential fluoroscopic images were taken in the sagittal plane during loaded knee bending motion. In vivo kinematics were analyzed using a two- to three-dimensional registration technique, which uses computer-assisted design models to reproduce the spatial position of femoral and tibial components from single-view fluoroscopic images. The average femoral component demonstrated 13.4 degrees external axial rotation for 0-120 degrees flexion. On average, the medial condyle moved anteriorly 6.2 mm for 0-100 degrees flexion, then posteriorly 4.0 mm for 100-120 degrees flexion. On average, the lateral condyle moved anteriorly 1.0 mm for 0-40 degrees flexion, then posteriorly 8.7 mm for 40-120 degrees flexion. The typical subject exhibited a lateral pivot pattern from extension to 60 degrees flexion and a central pivot pattern from 60 degrees to 100 degrees flexion, patterns that are not usually observed in normal knees. Subsequently from 100 degrees to 120 degrees flexion, a rollback pattern was reproduced in which bilateral condyles moved backward.

Entities:  

Mesh:

Year:  2004        PMID: 15304277     DOI: 10.1016/j.orthres.2003.12.013

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  11 in total

1.  Three-dimensional motion study of femur, tibia, and patella at the knee joint from bi-plane fluoroscopy and CT images.

Authors:  Takashi Ohnishi; Masahiko Suzuki; Atsushi Nawata; Shinji Naomoto; Tetsuji Iwasaki; Hideaki Haneishi
Journal:  Radiol Phys Technol       Date:  2010-04-03

2.  Effect of posterior design changes on postoperative flexion angle in cruciate retaining mobile-bearing total knee arthroplasty.

Authors:  Shigeyoshi Tsuji; Tetsuya Tomita; Hideo Hashimoto; Masakazu Fujii; Hideki Yoshikawa; Kazuomi Sugamoto
Journal:  Int Orthop       Date:  2010-06-09       Impact factor: 3.075

3.  Mobility of the rotating platform in low contact stress knee arthroplasty is durable.

Authors:  Arthur Zürcher; Kim van Hutten; Jaap Harlaar; Ruud Pöll
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-10-16       Impact factor: 4.342

4.  In vivo three-dimensional kinematics of total elbow arthroplasty using fluoroscopic imaging.

Authors:  Kazuma Futai; Tetsuya Tomita; Takaharu Yamazaki; Tsuyoshi Murase; Hideki Yoshikawa; Kazuomi Sugamoto
Journal:  Int Orthop       Date:  2010-02-23       Impact factor: 3.075

5.  No difference between fixed- and mobile-bearing total knee arthroplasty in activities of daily living and pain: a randomized clinical trial.

Authors:  Joicemar Tarouco Amaro; Gustavo Gonçalves Arliani; Diego Costa Astur; Pedro Debieux; Camila Cohen Kaleka; Moises Cohen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-07       Impact factor: 4.342

6.  Robust 2D/3D registration for fast-flexion motion of the knee joint using hybrid optimization.

Authors:  Takashi Ohnishi; Masahiko Suzuki; Tatsuya Kobayashi; Shinji Naomoto; Tomoyuki Sukegawa; Atsushi Nawata; Hideaki Haneishi
Journal:  Radiol Phys Technol       Date:  2012-11-09

7.  In vivo kinematics of mobile-bearing total knee arthroplasty during deep knee bending under weight-bearing conditions.

Authors:  Kazuma Futai; Tetsuya Tomita; Takaharu Yamazaki; Masashi Tamaki; Hideki Yoshikawa; Kazuomi Sugamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-16       Impact factor: 4.342

8.  Lack of axial rotation in mobile-bearing knee designs.

Authors:  Ray C Wasielewski; Richard D Komistek; Sumesh M Zingde; Kate C Sheridan; Mohamed R Mahfouz
Journal:  Clin Orthop Relat Res       Date:  2008-06-26       Impact factor: 4.176

9.  In vivo kinematics of high-flex mobile-bearing total knee arthroplasty, with a new post-cam design, in deep knee bending motion.

Authors:  Masahiro Kurita; Tetsuya Tomita; Takaharu Yamazaki; Masakazu Fujii; Kazuma Futai; Norimasa Shimizu; Hideki Yoshikawa; Kazuomi Sugamoto
Journal:  Int Orthop       Date:  2012-10-19       Impact factor: 3.075

10.  Kinematic analysis of posterior-stabilized total knee arthroplasty during standing up from and sitting down on a chair.

Authors:  Takatomo Mine; Kenji Hoshi; Kazuyoshi Gamada; Koichiro Ihara; Hiroyuki Kawamura; Ryutaro Kuriyama; Ryo Date
Journal:  J Orthop Surg Res       Date:  2016-11-17       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.