BACKGROUND: Pulmonary vascular resistance (PVR) quantification is important in the treatment of children with pulmonary hypertension. The Fick principle, used to quantify pulmonary artery flow, may be a flawed technique. We describe a novel method of PVR quantification by the use of magnetic resonance (MR) flow data and invasive pressure measurements. METHODS AND RESULTS: In 24 patients with either suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment, PVR was calculated by the use of simultaneously acquired MR flow and invasive pressure measurements (condition 1). In 19 of the 24 patients, PVR was also calculated at 20 ppm nitric oxide +30% (condition 2) and at 20 ppm nitric oxide +100% oxygen (condition 3), with the use of the MR method. This method proved safe and feasible in all patients. In 15 of 19 patients, PVR calculated by Fick flow was compared with the MR method. At condition 1, Bland-Altman analysis revealed a bias of 2.3% (MR > Fick) and limits of agreement of 50.2% to -45.5%. At condition 2, there was poorer agreement (bias was 28%, and the limits of agreement were 151.3% to 95.2%). At condition 3, there was very poor agreement (bias was 54.2%, and the limits of agreement were 174.4% to -66.0%). CONCLUSIONS: We have demonstrated the feasibility of using simultaneous invasive pressure measurements and MR flow data to measure PVR in humans.
BACKGROUND: Pulmonary vascular resistance (PVR) quantification is important in the treatment of children with pulmonary hypertension. The Fick principle, used to quantify pulmonary artery flow, may be a flawed technique. We describe a novel method of PVR quantification by the use of magnetic resonance (MR) flow data and invasive pressure measurements. METHODS AND RESULTS: In 24 patients with either suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment, PVR was calculated by the use of simultaneously acquired MR flow and invasive pressure measurements (condition 1). In 19 of the 24 patients, PVR was also calculated at 20 ppm nitric oxide +30% (condition 2) and at 20 ppm nitric oxide +100% oxygen (condition 3), with the use of the MR method. This method proved safe and feasible in all patients. In 15 of 19 patients, PVR calculated by Fick flow was compared with the MR method. At condition 1, Bland-Altman analysis revealed a bias of 2.3% (MR > Fick) and limits of agreement of 50.2% to -45.5%. At condition 2, there was poorer agreement (bias was 28%, and the limits of agreement were 151.3% to 95.2%). At condition 3, there was very poor agreement (bias was 54.2%, and the limits of agreement were 174.4% to -66.0%). CONCLUSIONS: We have demonstrated the feasibility of using simultaneous invasive pressure measurements and MR flow data to measure PVR in humans.
Authors: Silvia Schievano; Claudio Capelli; Carol Young; Philipp Lurz; Johannes Nordmeyer; Catherine Owens; Philipp Bonhoeffer; Andrew M Taylor Journal: Eur Radiol Date: 2010-08-01 Impact factor: 5.315
Authors: Jonathan R Mazal; Toby Rogers; William H Schenke; Anthony Z Faranesh; Michael Hansen; Kendall O'Brien; Kanishka Ratnayaka; Robert J Lederman Journal: Radiol Technol Date: 2016 Jan-Feb
Authors: Tacy E Downing; Kevin K Whitehead; Yoav Dori; Matthew J Gillespie; Matthew A Harris; Mark A Fogel; Jonathan J Rome; Andrew C Glatz Journal: Circ Cardiovasc Imaging Date: 2013-10-04 Impact factor: 7.792
Authors: Philip J Kilner; Tal Geva; Harald Kaemmerer; Pedro T Trindade; Juerg Schwitter; Gary D Webb Journal: Eur Heart J Date: 2010-01-11 Impact factor: 29.983