Literature DB >> 15298437

Effects of an artery/vascular graft compliance mismatch on protein transport: a numerical study.

Sandy F C Stewart1, Donald J Lyman.   

Abstract

Small-diameter vascular graft failure by intimal hyperplasia and thrombosis may result from flow disturbances and disruption of chemical transport in the fluid at the distal anastomosis, because of compliance mismatch between the graft and host artery. In previous studies. lower-than-normal wall shear stress (WSS), particle trapping, and high particle residence times were observed at the distal anastomosis due to a pulsatile tubular expansion effect caused by nonuniform radial deformations. This study was undertaken to examine effects of compliance and radius mismatch on the distribution of a model protein released at the graft-fluid interface. Finite element simulations of end-to-end vascular grafting were performed under pulsatile flow, using fluid-structure coupling to give physiologic wall displacements. Results showed that protein is convected smoothly downstream in a uniform compliant tube. A compliance mismatch disturbed the transport, causing positive and negative gradients in the concentration profile at the distal anastomosis. This was seen when the graft and artery radii were matched at zero pressure and at mean arterial pressure; low WSSs were only observed in the former case. Thus the distal intimal hypertrophy seen in noncompliant grafts may be caused partly by decreased WSS, and partly by concentration gradients of dissolved chemicals affecting chemotaxis of cells.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15298437     DOI: 10.1023/b:abme.0000032462.56207.65

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  10 in total

1.  Fabricating mechanically improved silk-based vascular grafts by solution control of the gel-spinning process.

Authors:  Maria Rodriguez; Jonathan A Kluge; Daniel Smoot; Matthew A Kluge; Daniel F Schmidt; Christopher R Paetsch; Peter S Kim; David L Kaplan
Journal:  Biomaterials       Date:  2019-10-23       Impact factor: 12.479

2.  Computationally optimizing the compliance of multilayered biomimetic tissue engineered vascular grafts.

Authors:  Ehab Akram Tamimi; Diana Catalina Ardila; Burt D Ensley; Robert S Kellar; Jonathan Vande Geest
Journal:  J Biomech Eng       Date:  2019-02-19       Impact factor: 2.097

3.  Biaxial Stretch Improves Elastic Fiber Maturation, Collagen Arrangement, and Mechanical Properties in Engineered Arteries.

Authors:  Angela H Huang; Jenna L Balestrini; Brooks V Udelsman; Kevin C Zhou; Liping Zhao; Jacopo Ferruzzi; Barry C Starcher; Michael J Levene; Jay D Humphrey; Laura E Niklason
Journal:  Tissue Eng Part C Methods       Date:  2016-06       Impact factor: 3.056

Review 4.  Current understanding of intimal hyperplasia and effect of compliance in synthetic small diameter vascular grafts.

Authors:  YeJin Jeong; Yuan Yao; Evelyn K F Yim
Journal:  Biomater Sci       Date:  2020-07-09       Impact factor: 6.843

5.  Acute Elution of TGFβ2 Affects the Smooth Muscle Cells in a Compliance-Matched Vascular Graft.

Authors:  Kenneth J Furdella; Shinichi Higuchi; Kang Kim; Tom Doetschman; William R Wagner; Jonathan P Vande Geest
Journal:  Tissue Eng Part A       Date:  2022-07       Impact factor: 4.080

6.  Physiologic compliance in engineered small-diameter arterial constructs based on an elastomeric substrate.

Authors:  Peter M Crapo; Yadong Wang
Journal:  Biomaterials       Date:  2009-12-03       Impact factor: 12.479

7.  In-vivo assessment of a tissue engineered vascular graft computationally optimized for target vessel compliance.

Authors:  Kenneth J Furdella; Shinichi Higuchi; Ali Behrangzade; Kang Kim; William R Wagner; Jonathan P Vande Geest
Journal:  Acta Biomater       Date:  2021-01-20       Impact factor: 8.947

8.  Experimental validation of convection-diffusion discretisation scheme employed for computational modelling of biological mass transport.

Authors:  Gráinne T Carroll; Paul D Devereux; David N Ku; Timothy M McGloughlin; Michael T Walsh
Journal:  Biomed Eng Online       Date:  2010-07-19       Impact factor: 2.819

Review 9.  Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

Authors:  Dhanjoo N Ghista; Foad Kabinejadian
Journal:  Biomed Eng Online       Date:  2013-12-13       Impact factor: 2.819

10.  Mechanical Assessment and Hyperelastic Modeling of Polyurethanes for the Early Stages of Vascular Graft Design.

Authors:  Arévalo-Alquichire Said; Dominguez-Paz Carlos; Valero Manuel F
Journal:  Materials (Basel)       Date:  2020-11-05       Impact factor: 3.623

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.