Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery.

Tom N Hoel1, Vibeke Videm, Svein T Baksaas, Tom E Mollnes, Frank Brosstad, Jan L Svennevig.   

Abstract

BACKGROUND: Cardiopulmonary bypass (CPB) evokes a systemic inflammatory response. In attempting to improve the biocompatibility of the equipment, various methods to coat the inner surfaces of the CPB systems have been developed. The present study compares a Trillium Biopassive surface-coated Affinity oxygenator with a Duraflo II totally heparin-coated CPB system.
METHODS: Low-risk patients admitted for primary coronary artery bypass grafting or aortic valve replacement were randomized to operation using the Trillium- or the Duraflo II-coated setups. Heparin concentration, complement activation (C3bc activation products and terminal complement complex (TCC)), platelet activation (platelet numbers and beta-thromboglobulin (BTG)), leukocyte activation (leukocyte numbers and myeloperoxidase (MPO)), coagulation (thrombin/antithrombin complexes (TAT)) and fibrinolytic activity (plasmin/alpha2-antiplasmin complexes (PAP)) were measured during CPB and two hours postoperatively.
RESULTS: Platelet counts decreased during CPB, without significant intergroup differences. The median BTG concentration increased moderately in both groups and were slightly higher in the Trillium group during CPB (p < 0.05), but not postoperatively. Complement activation products (C3bc and TCC), leukocyte counts, MPO, TAT and PAP activity showed no differences between the two groups.
CONCLUSIONS: There were small differences in the inflammatory response between the two extracorporeal circulation devices compared in this study.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15298426     DOI: 10.1191/0267659104pf737oa

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  4 in total

Review 1.  Attenuating the Systemic Inflammatory Response to Adult Cardiopulmonary Bypass: A Critical Review of the Evidence Base.

Authors:  R Clive Landis; Jeremiah R Brown; David Fitzgerald; Donald S Likosky; Linda Shore-Lesserson; Robert A Baker; John W Hammon
Journal:  J Extra Corpor Technol       Date:  2014-09

2.  Oxygenator safety evaluation: a focus on connection grip strength and arterial temperature measurement accuracy.

Authors:  Richard F Newland; Robert A Baker; Andrew J Sanderson; Sigrid C Tuble; Phil J Tully
Journal:  J Extra Corpor Technol       Date:  2012-06

Review 3.  Is a fully heparin-bonded cardiopulmonary bypass circuit superior to a standard cardiopulmonary bypass circuit?

Authors:  Sarah Mahmood; Haris Bilal; Mahvash Zaman; Augustine Tang
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-01-06

4.  Toward an artificial endothelium: Development of blood-compatible surfaces for extracorporeal life support.

Authors:  Teryn R Roberts; Mark R S Garren; Hitesh Handa; Andriy I Batchinsky
Journal:  J Trauma Acute Care Surg       Date:  2020-08       Impact factor: 3.697

  4 in total