Literature DB >> 15293014

Refining the measurement of rate constants in the BIAcore.

David A Edwards1.   

Abstract

When estimating rate constants using the BIAcore surface plasmon resonance (SPR) biosensor, one must have an accurate mathematical model to interpret sensogram data. Several models of differing complexity are discussed, including the effective rate constant (ERC) approach. This model can be shown formally to be good within O(Da) in the limit of small Damköhler number Da, which is the ratio of the reaction rate to the rate of transport to the surface. Numerical results are presented that show that except for very slow reactions, parameter estimates from the ERC model are very close to those estimated using a more complicated model. The BIAcore measures the behavior of an evanescent wave whose signal strength decays as it penetrates into the device. It is shown that this decay does not appreciably affect the sensogram readout at low Da, but at moderate Da can lead to situations where two vastly different rate constants can produce the same short-time sensogram data.

Mesh:

Substances:

Year:  2004        PMID: 15293014     DOI: 10.1007/s00285-004-0270-x

Source DB:  PubMed          Journal:  J Math Biol        ISSN: 0303-6812            Impact factor:   2.259


  25 in total

1.  Effective rate models for the analysis of transport-dependent biosensor data.

Authors:  T Mason; A R Pineda; C Wofsy; B Goldstein
Journal:  Math Biosci       Date:  1999-07       Impact factor: 2.144

2.  Effective rate models for receptors distributed in a layer above a surface: application to cells and Biacore.

Authors:  Carla Wofsy; Byron Goldstein
Journal:  Biophys J       Date:  2002-04       Impact factor: 4.033

3.  Kinetic analysis of monoclonal antibody-antigen interactions with a new biosensor based analytical system.

Authors:  R Karlsson; A Michaelsson; L Mattsson
Journal:  J Immunol Methods       Date:  1991-12-15       Impact factor: 2.303

Review 4.  The effect of flow and mass transport in thrombogenesis.

Authors:  D Basmadjian
Journal:  Ann Biomed Eng       Date:  1990       Impact factor: 3.934

5.  Analysis of mass transport-limited binding kinetics in evanescent wave biosensors.

Authors:  P Schuck; A P Minton
Journal:  Anal Biochem       Date:  1996-09-05       Impact factor: 3.365

Review 6.  Theoretical analysis of protein concentration determination using biosensor technology under conditions of partial mass transport limitation.

Authors:  L L Christensen
Journal:  Anal Biochem       Date:  1997-07-01       Impact factor: 3.365

7.  Kinetics of ligand binding to receptor immobilized in a polymer matrix, as detected with an evanescent wave biosensor. I. A computer simulation of the influence of mass transport.

Authors:  P Schuck
Journal:  Biophys J       Date:  1996-03       Impact factor: 4.033

8.  An analysis of transport resistances in the operation of BIAcore; implications for kinetic studies of biospecific interactions.

Authors:  M L Yarmush; D B Patankar; D M Yarmush
Journal:  Mol Immunol       Date:  1996-10       Impact factor: 4.407

9.  Approximating the effects of diffusion on reversible reactions at the cell surface: ligand-receptor kinetics.

Authors:  B Goldstein; M Dembo
Journal:  Biophys J       Date:  1995-04       Impact factor: 4.033

10.  Investigation of the interaction between the class I MHC-related Fc receptor and its immunoglobulin G ligand.

Authors:  M Raghavan; M Y Chen; L N Gastinel; P J Bjorkman
Journal:  Immunity       Date:  1994-07       Impact factor: 31.745

View more
  2 in total

1.  Receptor heterogeneity in optical biosensors.

Authors:  Ryan M Evans; David A Edwards
Journal:  J Math Biol       Date:  2017-07-13       Impact factor: 2.259

Review 2.  Kinetic studies of biological interactions by affinity chromatography.

Authors:  John E Schiel; David S Hage
Journal:  J Sep Sci       Date:  2009-05       Impact factor: 3.645

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.