Literature DB >> 1529137

Gastrointestinal examinations with digital radiography.

M Takahashi1, S Ueno, S Yoshimatsu, Y Higashida, T Tsuchigame, K Ito, M Hara, T Takada, M Kamiya, A Yoshida.   

Abstract

Basic imaging properties and clinical usefulness of an upgraded digital radiography system were evaluated. The system, which has 1,024 x 1,024 and 2,048 x 2,048 matrices, was upgraded with smaller focal spots (0.3 and 0.8 mm) and reduced thickness of the photoconductive layer of the video camera. Screen-film and digital images (with and without postprocessing) of the upper and lower gastrointestinal (GI) tract were used in the clinical evaluation. Overall modulation transfer functions of the upgraded digital system were comparable to those of the screen-film system, especially at the lower spatial frequency. Threshold contrasts of the two systems were similar despite a 50% reduction in incident exposure for the digital system. For the upper GI tract, digital images processed with unsharp masking techniques were comparable in quality to screen-film images before and after upgrade of the system. For the lower GI tract, screen-film images were better than digital images, except for those produced with a 2,048 x 2,048 matrix with unsharp masking. Further evaluation of the system for examination of other parts of the body seems warranted.

Entities:  

Mesh:

Year:  1992        PMID: 1529137     DOI: 10.1148/radiographics.12.5.1529137

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  4 in total

1.  Reassessment of barium radiographic examination in diagnosing gastrointestinal diseases.

Authors:  Jiu-Ru Chen
Journal:  World J Gastroenterol       Date:  1999-10       Impact factor: 5.742

2.  Gastrointestinal examinations with a 2,048- x 2,048-pixel image intensifier television digital radiography system.

Authors:  Y Baba; M Takahashi; T Tsuchigami; Y Higashida
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

3.  Double-contrast barium enema study with computed radiography: assessment in detection of colorectal polyps.

Authors:  Y Okada; S Kusano; T Endo
Journal:  J Digit Imaging       Date:  1994-08       Impact factor: 4.056

4.  Clinical usefulness of digital radiography in the gastrointestinal tract: efficacy of magnification method.

Authors:  Y Sugino; Y Imai; H Fujisawa; K Hiramatsu; H Amoh; K Kumakura
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.