Initial stability of ankle arthrodesis with three-screw fixation. A finite element analysis.

Ana Alonso-Vázquez1, Henrik Lauge-Pedersen, Lars Lidgren, Mark Taylor.   

Abstract

OBJECTIVE: Compare the initial stability at the fusion site of ankle arthrodesis fixed with two and three screws.
DESIGN: Finite element models of ankle arthrodesis were developed from computed tomography images. Two-screw constructs were augmented with a third screw in different orientations and subjected to loads likely to affect the ankle postoperatively.
BACKGROUND: More stable fixation seems to increase the chance of fusion, as it minimises the motion between the tibiotalar interfaces.
METHODS: Non-linear elastic finite element analyses were performed in external torsion and dorsiflexion. The micromotions at the tibiotalar interface were computed to compare the two- and three-screw fixation in intact and flat-cut arthrodesis.
RESULTS: Adding a third screw reduced the micromotions at the fusion site. Inserting the third screw anteriorly predicted lower peak micromotions than inserting the screw posteriorly, except for the intact arthrodesis tested in dorsiflexion. Three-screw intact arthrodesis predicted lower peak micromotions than flat-cut arthrodesis.
CONCLUSIONS: Better stability was predicted for three-screw ankle arthrodesis. In flat-cut arthrodesis, a third screw inserted anteriorly performed better than a posterior screw. In intact arthrodesis, a posterior screw seemed a better option when flexion stability was the main concern. Even with three-screw fixation, the configuration of the first two-crossed screws may still be important to improve the stability at the fusion site.

Entities:  

Mesh:

Year:  2004        PMID: 15288463     DOI: 10.1016/j.clinbiomech.2004.04.014

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  11 in total

1.  Biomechanical evaluation of tenodesis reconstruction in ankle with deltoid ligament deficiency: a finite element analysis.

Authors:  Can Xu; Ming-Yan Zhang; Guang-Hua Lei; Can Zhang; Shu-Guang Gao; Wen Ting; Kang-Hua Li
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-11       Impact factor: 4.342

2.  Buttressing angle of the double-plating fixation of a distal radius fracture: a finite element study.

Authors:  Chun-Li Lin; Yu-Hao Lin; Alvin Chao-Yu Chen
Journal:  Med Biol Eng Comput       Date:  2006-07-11       Impact factor: 2.602

3.  Optimal double screw configuration for subtalar arthrodesis: a finite element analysis.

Authors:  Jun Young Lee; Yeon Soo Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-11       Impact factor: 4.342

4.  Popliteal block with transfibular approach in ankle arthrodesis: a case series.

Authors:  Gabriel A Akra; Alan Middleton; Akinwande O Adedapo; Paul Finn
Journal:  J Med Case Rep       Date:  2010-05-12

5.  Use of three-dimensional finite element models of the lateral ankle ligaments to evaluate three surgical techniques.

Authors:  Cheng-Wei Wang; Aikeremujiang Muheremu; Jing-Ping Bai
Journal:  J Int Med Res       Date:  2017-09-12       Impact factor: 1.671

6.  PRE-PLANNING ANKLE ARTHRODESIS USING 3D RECONSTRUCTED TOMOGRAPHIES.

Authors:  Rodrigo Schroll Astolfi; Marcio DE Paiva Bezerra Carrah; Guilherme Farias Cordeiro; Jailson Rodrigues Lopes; Manuel Joaquim Diógenes Teixeira; José Alberto Dias Leite
Journal:  Acta Ortop Bras       Date:  2020 Mar-Apr       Impact factor: 0.513

7.  Initial stability and stress distribution of ankle arthroscopic arthrodesis with three kinds of 2-screw configuration fixation: a finite element analysis.

Authors:  Min Zhu; Cheng-Song Yuan; Zhong-Min Jin; Yun-Jiao Wang; You-Xing Shi; Zhi-Jin Yang; Kanglai Tang
Journal:  J Orthop Surg Res       Date:  2018-10-20       Impact factor: 2.359

8.  Effects of Ankle Arthrodesis on Biomechanical Performance of the Entire Foot.

Authors:  Yan Wang; Zengyong Li; Duo Wai-Chi Wong; Ming Zhang
Journal:  PLoS One       Date:  2015-07-29       Impact factor: 3.240

9.  Finite element analysis of the initial stability of arthroscopic ankle arthrodesis with three-screw fixation: posteromedial versus posterolateral home-run screw.

Authors:  Sen Wang; Jian Yu; Xin Ma; Dahang Zhao; Xiang Geng; Jiazhang Huang; Xu Wang
Journal:  J Orthop Surg Res       Date:  2020-07-10       Impact factor: 2.359

10.  Impact of Modeling Assumptions on Stability Predictions in Reverse Total Shoulder Arthroplasty.

Authors:  Mehul A Dharia; Jeffrey E Bischoff; David Schneider
Journal:  Front Physiol       Date:  2018-08-21       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.