Literature DB >> 15288036

3 Tesla magnetic resonance imaging of the prostate with combined pelvic phased-array and endorectal coils; Initial experience(1).

B Nicolas Bloch1, Neil M Rofsky, Ronaldo H Baroni, Robert P Marquis, Ivan Pedrosa, Robert E Lenkinski.   

Abstract

RATIONALE AND
OBJECTIVES: High-resolution magnetic resonance imaging of the prostate at 1.5T has gained acceptance for pretherapeutic staging of prostate cancer. The aim of this study was to evaluate the potential clinical utility of combined pelvic phased-array and endorectal coils at 3T.
MATERIALS AND METHODS: Six volunteers were examined on 1.5T and 3T scanners with pelvic phased-array surface coil combined with a disposable endorectal prostate coil.
RESULTS: We were able to acquire T2-W fast spin echo images with 1.5 mm slices, field of view 12, matrix 320 x 192, (voxel size 0.35 mm(3)), with excellent anatomic detail and good T2 contrast. A 1.5 mm axial slice thickness permitted high-quality multiplanar reconstructions with clear visualization of small patho-anatomic structures. Dynamic contrast-enhanced gradient echo images showed excellent spatial resolution (voxel size, 0.38 mm(3)) and temporal resolution. With this level of anatomic information in dynamic images we could clearly distinguish between intracapsular and extracapsular contrast enhancement.
CONCLUSION: Using modified T2-fast spin echo and dynamic contrast-enhanced gradient echo sequences, we obtained whole gland coverage with 35-38 microm(3) resolution, without interfering artifacts, in reasonable acquisition times and staying well below the specific absorption rate guidelines. The high spatial resolution in the axial plane allowed meaningful multiplanar reconstructions. The initial results show the clinical utility of endorectal 3T for the noninvasive evaluation of the prostate with image features and quality not achievable at 1.5 T.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15288036     DOI: 10.1016/j.acra.2004.04.017

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  29 in total

1.  Prediction of prostate cancer extracapsular extension with high spatial resolution dynamic contrast-enhanced 3-T MRI.

Authors:  B Nicolas Bloch; Elizabeth M Genega; Daniel N Costa; Ivan Pedrosa; Martin P Smith; Herbert Y Kressel; Long Ngo; Martin G Sanda; William C Dewolf; Neil M Rofsky
Journal:  Eur Radiol       Date:  2012-06-03       Impact factor: 5.315

Review 2.  Technological advances in radiation therapy for prostate cancer.

Authors:  Mehee Choi; Arthur Y Hung
Journal:  Curr Urol Rep       Date:  2010-05       Impact factor: 3.092

Review 3.  Whole-body MRI at high field: technical limits and clinical potential.

Authors:  Fritz Schick
Journal:  Eur Radiol       Date:  2005-01-27       Impact factor: 5.315

Review 4.  Prostate MR imaging at high-field strength: evolution or revolution?

Authors:  Olivier Rouvière; Robert P Hartman; Denis Lyonnet
Journal:  Eur Radiol       Date:  2005-09-10       Impact factor: 5.315

5.  [MR techniques for noninvasive diagnosis of prostate cancer].

Authors:  N Morakkabati-Spitz; P J Bastian; A Meissner; F Träber; J Gieseke; H H Schild; S C Müller
Journal:  Urologe A       Date:  2006-06       Impact factor: 0.639

6.  Two-dimensional MR spectroscopy of healthy and cancerous prostates in vivo.

Authors:  M Albert Thomas; Thomas Lange; S Sendhil Velan; Rajakumar Nagarajan; Steve Raman; Ana Gomez; Daniel Margolis; Stephany Swart; Raymond R Raylman; Rolf F Schulte; Peter Boesiger
Journal:  MAGMA       Date:  2008-07-17       Impact factor: 2.310

7.  Software strategy for robotic transperineal prostate therapy in closed-bore MRI.

Authors:  Junichi Tokuda; Gregory S Fischer; Csaba Csoma; Simon P DiMaio; David G Gobbi; Gabor Fichtinger; Clare M Tempany; Nobuhiko Hata
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

8.  The role of magnetic resonance imaging (MRI) in prostate cancer imaging and staging at 1.5 and 3 Tesla: the Beth Israel Deaconess Medical Center (BIDMC) approach.

Authors:  B Nicolas Bloch; Robert E Lenkinski; Neil M Rofsky
Journal:  Cancer Biomark       Date:  2008       Impact factor: 4.388

9.  Influence of imaging and histological factors on prostate cancer detection and localisation on multiparametric MRI: a prospective study.

Authors:  Flavie Bratan; Emilie Niaf; Christelle Melodelima; Anne Laure Chesnais; Rémi Souchon; Florence Mège-Lechevallier; Marc Colombel; Olivier Rouvière
Journal:  Eur Radiol       Date:  2013-03-15       Impact factor: 5.315

10.  Image-guided radio-frequency gain calibration for high-field MRI.

Authors:  Elodie Breton; Kellyanne McGorty; Graham C Wiggins; Leon Axel; Daniel Kim
Journal:  NMR Biomed       Date:  2009-12-15       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.