Literature DB >> 15284436

Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging.

Timothy F Christian1, Dan W Rettmann, Anthony H Aletras, Steve L Liao, Joni L Taylor, Robert S Balaban, Andrew E Arai.   

Abstract

PURPOSE: To compare fluorescent microsphere measurements of myocardial blood flow (MBF) with qualitative, semiquantitative, and fully quantitative measurements of first-pass perfusion at magnetic resonance (MR) imaging.
MATERIALS AND METHODS: Coronary artery occlusion or intracoronary adenosine infusion was successfully performed in 16 beagles; both procedures were performed simultaneously in one animal. MBF was assessed at microsphere analysis. First-pass myocardial perfusion MR imaging was performed during a dual-bolus administration of gadopentetate dimeglumine (0.0025 mmol/kg followed by 0.10 mmol/kg). The absolute myocardial perfusion at MR imaging was calculated by using Fermi function deconvolution methods. Qualitative, semiquantitative, and absolute myocardial perfusion MR imaging measurements were compared with microsphere MBF measurements by using paired t tests, linear correlation, and Bland-Altman analysis.
RESULTS: Fully quantitative (ie, absolute) analysis of MBF at MR imaging correlated with microsphere MBF measurement (r = 0.95, P <.001) across the full range of blood flow rates encountered (from 0 to >5.0 mL/min/g). Similar close correlations were observed in endocardial and epicardial segments (representing approximately 0.85 g of the myocardium). With modest increases in MBF, qualitative measurements plateaued in the hyperemic zones. Semiquantitative measurements did not correlate with MBF as well (r = 0.69-0.89); they plateaued around 3.0 mL/min/g.
CONCLUSION: Dual-bolus MR imaging enabled accurate measurement of absolute epicardial and endocardial perfusion across a wide range of blood flow rates (0 to >5.0 mL/min/g). Use of qualitative MR imaging measures such as the contrast enhancement ratio led to substantially underestimated hyperemic blood flow measurements. Copyright RSNA, 2004

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15284436     DOI: 10.1148/radiol.2323030573

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  106 in total

Review 1.  Contrast agents and cardiac MR imaging of myocardial ischemia: from bench to bedside.

Authors:  Pierre Croisille; Didier Revel; Maythem Saeed
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

2.  Endocardial and epicardial myocardial perfusion determined by semi-quantitative and quantitative myocardial perfusion magnetic resonance.

Authors:  Abdulghani Larghat; John Biglands; Neil Maredia; John P Greenwood; Stephen G Ball; Michael Jerosch-Herold; Aleksandra Radjenovic; Sven Plein
Journal:  Int J Cardiovasc Imaging       Date:  2011-11-29       Impact factor: 2.357

Review 3.  Quantitative and qualitative analysis and interpretation of CT perfusion imaging.

Authors:  Carolina Valdiviezo; Marietta Ambrose; Vishal Mehra; Albert C Lardo; Joao A C Lima; Richard T George
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

Review 4.  Left main coronary artery disease: A review of the spectrum of noninvasive diagnostic modalities.

Authors:  Nishtha Sareen; Karthik Ananthasubramaniam
Journal:  J Nucl Cardiol       Date:  2015-10-20       Impact factor: 5.952

Review 5.  Reasons and implications of agreements and disagreements between coronary flow reserve, fractional flow reserve, and myocardial perfusion imaging.

Authors:  Manish Motwani; Mahsaw Motlagh; Anuj Gupta; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2015-12-29       Impact factor: 5.952

Review 6.  Magnetic resonance approaches and recent advances in myocardial perfusion imaging.

Authors:  Daniel C Lee; Francis J Klocke
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

7.  Magnetic resonance myocardial perfusion imaging: a new era in the detection of reversible myocardial ischaemia.

Authors:  S Watkins; K G Oldroyd; S Frohwein
Journal:  Heart       Date:  2006-08-11       Impact factor: 5.994

8.  T2* measurement during first-pass contrast-enhanced cardiac perfusion imaging.

Authors:  Peter Kellman; Anthony H Aletras; Li-Yueh Hsu; Elliot R McVeigh; Andrew E Arai
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

9.  Diagnostic accuracy of stress perfusion CMR in comparison with quantitative coronary angiography: fully quantitative, semiquantitative, and qualitative assessment.

Authors:  Federico E Mordini; Tariq Haddad; Li-Yueh Hsu; Peter Kellman; Tracy B Lowrey; Anthony H Aletras; W Patricia Bandettini; Andrew E Arai
Journal:  JACC Cardiovasc Imaging       Date:  2014-01

10.  Automatic postprocessing for the assessment of quantitative human myocardial perfusion using MRI.

Authors:  Andreas Max Weng; Christian Oliver Ritter; Joachim Lotz; Meinrad Joachim Beer; Dietbert Hahn; Herbert Köstler
Journal:  Eur Radiol       Date:  2009-12-17       Impact factor: 5.315