Literature DB >> 15282803

Sensitivity-encoded coronary MRA at 3T.

Michael E Huber1, Sebastian Kozerke, Klaas P Pruessmann, Jouke Smink, Peter Boesiger.   

Abstract

Long scan times are still a main limitation in free-breathing navigator-gated 3D coronary MR angiography (MRA). Unlike other MRI applications, high-resolution coronary MRA has not been amenable to acceleration by parallel imaging techniques due to signal-to-noise ratio (SNR) concerns. In the present work, mitigating SNR limitations by the transition to higher static magnetic field strength is proposed, thus enabling scan time reduction by the parallel sensitivity encoding (SENSE) technique. The study reports the implementation and evaluation of free-breathing navigator-gated 3D coronary MRA with SENSE at 3T. Results from 11 healthy subjects indicate that the approach permits significant scan time reduction in MRA of the left and right coronary systems. Quantitative image analysis and visual grading suggest that two-fold scan acceleration can be accomplished at nearly preserved image quality. The additional experiments appear to demonstrate that parallel MRA equally permits enhancing volume coverage and spatial resolution while maintaining scan time.

Mesh:

Year:  2004        PMID: 15282803     DOI: 10.1002/mrm.20062

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

Authors:  Bernd J Wintersperger; Spencer Sincleair; Val M Runge; Olaf Dietrich; Armin Huber; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

Review 2.  MR imaging of the coronary vasculature: imaging the lumen, wall, and beyond.

Authors:  Kai Lin; James C Carr
Journal:  Radiol Clin North Am       Date:  2015-03       Impact factor: 2.303

Review 3.  Whole-body MRI at high field: technical limits and clinical potential.

Authors:  Fritz Schick
Journal:  Eur Radiol       Date:  2005-01-27       Impact factor: 5.315

4.  High-resolution steady-state free precession coronary magnetic resonance angiography within a breath-hold: parallel imaging with extended cardiac data acquisition.

Authors:  Jaeseok Park; Andrew C Larson; Qiang Zhang; Orlando Simonetti; Debiao Li
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

5.  Coronary vessel-wall and lumen imaging using radial k-space acquisition with MRI at 3 Tesla.

Authors:  Andrew N Priest; P Martin Bansmann; Kai Müllerleile; Gerhard Adam
Journal:  Eur Radiol       Date:  2006-10-05       Impact factor: 5.315

6.  Coronary MR angiography at 3T during diastole and systole.

Authors:  Ahmed M Gharib; Daniel A Herzka; Ali O Ustun; Milind Y Desai; Julia Locklin; Roderic I Pettigrew; Matthias Stuber
Journal:  J Magn Reson Imaging       Date:  2007-10       Impact factor: 4.813

7.  3D MR coronary angiography: optimization of the technique and preliminary results.

Authors:  Niek Hendrik Jan Prakken; Evert-Jan P A Vonken; Birgitta K Velthuis; Pieter A F M Doevendans; Maarten-Jan M Cramer
Journal:  Int J Cardiovasc Imaging       Date:  2006-03-15       Impact factor: 2.357

8.  3-T navigator parallel-imaging coronary MR angiography: targeted-volume versus whole-heart acquisition.

Authors:  Shixin Chang; Matthew D Cham; Shuguang Hu; Yi Wang
Journal:  AJR Am J Roentgenol       Date:  2008-07       Impact factor: 3.959

9.  Clinical applications for cardiovascular magnetic resonance imaging at 3 tesla.

Authors:  Allison G Hays; Michael Schär; Sebastian Kelle
Journal:  Curr Cardiol Rev       Date:  2009-08

10.  Feasibility and diagnostic accuracy of whole heart coronary MR angiography using free-breathing 3D balanced turbo-field-echo with SENSE and the half-fourier acquisition technique.

Authors:  Young Jin Kim; Jae-Seung Seo; Byoung Wook Choi; Kyu Ok Choe; Yangsoo Jang; Young-Guk Ko
Journal:  Korean J Radiol       Date:  2006 Oct-Dec       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.