Literature DB >> 15271012

Ablation lesion size correlates with pacing threshold: a physiological basis for use of pacing to assess ablation lesions.

John L Sapp1, Kyoko Soejima, Joshua M Cooper, Laurence M Epstein, William G Stevenson.   

Abstract

The virtual electrode model predicts that pacing stimulus strength should reflect proximity of the pacing electrode to excitable myocardium, allowing pacing threshold to assess radiofrequency (RF) ablation lesions and unexcitable scar. The purpose of this study is to correlate RF lesion size with pacing threshold and electrogram (EG) amplitude change at the ablation site. In four swine (32-58 kg, 20 ventricular RF lesions were created using a 4-mm tip electrode catheters under fluoroscopic and electroanatomic guidance. Unipolar pacing threshold and bipolar and unipolar EG amplitude were measured before and after ablation and compared with lesion size measured in the fixed, serially sectioned tissue. Lesion diameter ranged from 6.4 to 19 mm and volume ranged from 29 to 1920 mm3. Ablation increased the pacing threshold by 320%, from 0.9 +/- 0.3 to 3.6 +/- 2.6 mA, P < 0.001. The change in pacing threshold correlated with lesion volume R = 0.88, P < 0.001). Linear regression predicts that lesion volume (mm3) = 160 X rise in pacing threshold + 13. Ablation reduced peak to peak bipolar EG amplitude by 56%, from 2.5 +/- 2.0 mV to 1.1 +/- 0.6 mV (P = 0.005). Unipolar EG amplitude diminished by only 22% from 4.0 +/- 1.6 to 3.2 +/- 0.9 mV postablation (P = 0.005). The correlations of lesion volume with change in either bipolar R = 0.14, P = 0.6) or unipolar R = 0.18, P = 0.6) EG amplitude were poor. Pacing threshold correlates with RF ablation lesion size, consistent with the virtual electrode model. In normal myocardium, change in pacing threshold is likely to be a better marker of lesion size than electrogram amplitude.

Entities:  

Mesh:

Year:  2004        PMID: 15271012     DOI: 10.1111/j.1540-8159.2004.00561.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  J Interv Card Electrophysiol       Date:  2020-10       Impact factor: 1.900

2.  Feasibility of directional percutaneous epicardial ablation with a partially insulated catheter.

Authors:  Ammar M Killu; Niyada Naksuk; Faisal F Syed; Christopher V DeSimone; Prakriti Gaba; Chance Witt; Dorothy J Ladewig; Scott H Suddendorf; Joanne M Powers; Gaurav Satam; Zdeněk Stárek; Tomas Kara; Jiří Wolf; Pavel Leinveber; Michal Crha; Miroslav Novák; Charles J Bruce; Paul A Friedman; Samuel J Asirvatham
Journal:  J Interv Card Electrophysiol       Date:  2018-07-14       Impact factor: 1.900

3.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Sáenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  Europace       Date:  2019-08-01       Impact factor: 5.214

Review 4.  Better Lesion Creation And Assessment During Catheter Ablation.

Authors:  Saurabh Kumar; Chirag R Barbhaiya; Samuel Balindger; Roy M John; Laurence M Epstein; Bruce A Koplan; Usha B Tedrow; William G Stevenson; Gregory F Michaud
Journal:  J Atr Fibrillation       Date:  2015-10-31

5.  Electrogram voltage and pacing threshold before ablation, measured by mini-electrodes, predict parameters indicative of transmural lesions in the human atrium.

Authors:  Carla Lázaro; Teresa Barrio-López; Eduardo Castellanos; Mercedes Ortiz; Martín Arceluz; Jesús Almendral
Journal:  J Interv Card Electrophysiol       Date:  2019-05-02       Impact factor: 1.900

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.