Literature DB >> 15265725

Molecular-beacon-based array for sensitive DNA analysis.

Gang Yao1, Weihong Tan.   

Abstract

Molecular beacon (MB) DNA probes provide a new way for sensitive label-free DNA/protein detection in homogeneous solution and biosensor development. However, a relatively low fluorescence enhancement after the hybridization of the surface-immobilized MB hinders its effective biotechnological applications. We have designed new molecular beacon probes to enable a larger separation between the surface and the surface-bound MBs. Using these MB probes, we have developed a DNA array on avidin-coated cover slips and have improved analytical sensitivity. A home-built wide-field optical setup was used for imaging the array. Our results show that linker length, pH, and ionic strength have obvious effects on the performance of the surface-bound MBs. The fluorescence enhancement of the new MBs after hybridization has been increased from 2 to 5.5. The MB-based DNA array could be used for DNA detection with high sensitivity, enabling simultaneous multiple-target bioanalysis in a variety of biotechnological applications.

Mesh:

Substances:

Year:  2004        PMID: 15265725     DOI: 10.1016/j.ab.2003.12.005

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  21 in total

1.  Coupling molecular beacons to barcoded metal nanowires for multiplexed, sealed chamber DNA bioassays.

Authors:  Rebecca L Stoermer; Kristin B Cederquist; Sean K McFarland; Michael Y Sha; Sharron G Penn; Christine D Keating
Journal:  J Am Chem Soc       Date:  2006-12-27       Impact factor: 15.419

2.  Molecular beacons in biomedical detection and clinical diagnosis.

Authors:  Youngmi Kim; Dosung Sohn; Weihong Tan
Journal:  Int J Clin Exp Pathol       Date:  2008-01-01

3.  Distance-dependent emission from dye-labeled oligonucleotides on striped Au/Ag nanowires: effect of secondary structure and hybridization efficiency.

Authors:  Rebecca L Stoermer; Christine D Keating
Journal:  J Am Chem Soc       Date:  2006-10-11       Impact factor: 15.419

4.  A droplet-based, optofluidic device for high-throughput, quantitative bioanalysis.

Authors:  Feng Guo; Michael Ian Lapsley; Ahmad Ahsan Nawaz; Yanhui Zhao; Sz-Chin Steven Lin; Yuchao Chen; Shikuan Yang; Xing-Zhong Zhao; Tony Jun Huang
Journal:  Anal Chem       Date:  2012-11-27       Impact factor: 6.986

5.  Quantitative rRNA-targeted solution-based hybridization assay using peptide nucleic acid molecular beacons.

Authors:  Xu Li; Eberhard Morgenroth; Lutgarde Raskin
Journal:  Appl Environ Microbiol       Date:  2008-09-26       Impact factor: 4.792

6.  Hybridization efficiency of molecular beacons bound to gold nanowires: effect of surface coverage and target length.

Authors:  Kristin B Cederquist; Christine D Keating
Journal:  Langmuir       Date:  2010-11-01       Impact factor: 3.882

7.  Locked nucleic acid based beacons for surface interaction studies and biosensor development.

Authors:  Karen Martinez; M-Carmen Estevez; Yanrong Wu; Joseph A Phillips; Colin D Medley; Weihong Tan
Journal:  Anal Chem       Date:  2009-05-01       Impact factor: 6.986

8.  Molecular beacon-metal nanowire interface: effect of probe sequence and surface coverage on sensor performance.

Authors:  Kristin B Cederquist; Rebecca Stoermer Golightly; Christine D Keating
Journal:  Langmuir       Date:  2008-07-15       Impact factor: 3.882

9.  Label-free microarray imaging for direct detection of DNA hybridization and single-nucleotide mismatches.

Authors:  Emre Ozkumur; Sunmin Ahn; Ayça Yalçin; Carlos A Lopez; Elif Cevik; Rostem J Irani; Charles DeLisi; Marcella Chiari; M Selim Unlü
Journal:  Biosens Bioelectron       Date:  2010-01-04       Impact factor: 10.618

10.  Towards a target label-free suboptimum oligonucleotide displacement-based detection system.

Authors:  Mònica Mir; Pablo Lozano-Sánchez; Ioanis Katakis
Journal:  Anal Bioanal Chem       Date:  2008-05-03       Impact factor: 4.142

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.