Progress toward the development of an implantable sensor for glucose.

G S Wilson1, Y Zhang, G Reach, D Moatti-Sirat, V Poitout, D R Thévenot, F Lemonnier, J C Klein.   

Abstract

The development of an electrochemically based implantable sensor for glucose is described. The sensor is needle-shaped, about the size of a 28-gauge needle. It is flexible and must be implanted subcutaneously by using a 21-gauge catheter, which is then removed. When combined with a monitoring unit, this device, based on the glucose oxidase-catalyzed oxidation of glucose, reliably monitors glucose concentrations for as long as 10 days in rats. Various design considerations, including the decision to monitor the hydrogen peroxide produced in the enzymatic reaction, are discussed. Glucose constitutes the most important future target analyte for continuous monitoring, but the basic methodology developed for glucose could be applied to several other analytes such as lactate or ascorbate. The success in implementation of such a device depends on a reaction of the tissue surrounding the implant so as not to interfere with the proper functioning of the sensor. Histochemical evidence indicates that the tissue response leads to enhanced sensor performance.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1525989

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  8 in total

1.  A percutaneous device to study glucose kinetics in subcutaneous tissue fluid.

Authors:  M Gerritsen; J A Lutterman; J A Jansen
Journal:  J Mater Sci Mater Med       Date:  2000-08       Impact factor: 3.896

2.  Evaluation of the tissue reaction to a percutaneous access device using titanium fibre mesh anchorage in goats.

Authors:  M Gerritsen; Y G Paquay; J A Jansen
Journal:  J Mater Sci Mater Med       Date:  1998-09       Impact factor: 3.896

3.  Youth and parent satisfaction with clinical use of the GlucoWatch G2 Biographer in the management of pediatric type 1 diabetes.

Authors: 
Journal:  Diabetes Care       Date:  2005-08       Impact factor: 19.112

4.  Neurometabolic coupling between neural activity, glucose, and lactate in activated visual cortex.

Authors:  Baowang Li; Ralph D Freeman
Journal:  J Neurochem       Date:  2015-05-29       Impact factor: 5.372

Review 5.  Biomaterials/tissue interactions: possible solutions to overcome foreign body response.

Authors:  Jacqueline M Morais; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  AAPS J       Date:  2010-02-09       Impact factor: 4.009

6.  A review of the biocompatibility of implantable devices: current challenges to overcome foreign body response.

Authors:  Yoshinori Onuki; Upkar Bhardwaj; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2008-11

7.  A review of the development of a vehicle for localized and controlled drug delivery for implantable biosensors.

Authors:  Upkar Bhardwaj; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2008-11

8.  Electrochemical sensor array for glucose monitoring fabricated by rapid immobilization of active glucose oxidase within photochemically polymerized hydrogels.

Authors:  Amos Mugweru; Becky L Clark; Michael V Pishko
Journal:  J Diabetes Sci Technol       Date:  2007-05
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.