Literature DB >> 15257358

Evaluation of the rupture of silicone breast implants by mammography, ultrasonography and magnetic resonance imaging in asymptomatic patients: correlation with surgical findings.

Anabel Medeiros Scaranelo1, Américo Ferreira Marques, Elizabeth Brenda Smialowski, Henriquel Manoel Lederman.   

Abstract

CONTEXT: Different imaging methods can identify the integrity of breast implants and also the extent of possible silicone leakage. Mammography, ultrasonography and magnetic resonance imaging are often used to evaluate the integrity of breast implants, usually in patients that are symptomatic for rupture. A group of clinically asymptomatic patients was taken as a sample. These patients wanted to remove or change their breast implants for psychological or cosmetic reasons.
OBJECTIVE: The purpose of this study was to compare the efficacy of mammography, sonography and magnetic resonance imaging in the detection of breast implant rupture in an asymptomatic population. TYPE OF STUDY: Prospective study.
SETTING: Department of Diagnostic Imaging, Universidade de São Paulo, São Paulo, Brazil.
METHODS: The participants were 44 asymptomatic patients who subsequently had implants surgically removed. Eighty-three implants were evaluated by both film-screen mammography and high-resolution sonography and 77 implants were evaluated by magnetic resonance imaging. The sensitivity and specificity of mammography, ultrasonography and magnetic resonance imaging were assessed using predetermined diagnostic criteria for implant rupture. All radiological signs were discussed and false positives and false negatives were retrospectively evaluated to identify the pitfalls in the investigations.
RESULTS: The respective sensitivity and specificity of mammography were 20% and 89%; sonography, 30% and 81%; and magnetic resonance imaging, 64% and 77%. The differences between patients with breast implants for cosmetic and oncological reasons were discussed.
CONCLUSIONS: Our experience suggests that magnetic resonance imaging seems to be the best imaging method on its own for the evaluation of rupturing among asymptomatic patients.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15257358     DOI: 10.1590/s1516-31802004000200002

Source DB:  PubMed          Journal:  Sao Paulo Med J        ISSN: 1516-3180            Impact factor:   1.044


  8 in total

1.  Study of breast implant rupture: MRI versus surgical findings.

Authors:  A Vestito; F F Mangieri; A Ancona; C Minervini; V Perchinunno; S Rinaldi
Journal:  Radiol Med       Date:  2012-03-19       Impact factor: 3.469

2.  MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard.

Authors:  M C Maijers; F B Niessen; J F H Veldhuizen; M J P F Ritt; R A Manoliu
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

Review 3.  The effect of study design biases on the diagnostic accuracy of magnetic resonance imaging for detecting silicone breast implant ruptures: a meta-analysis.

Authors:  Jae W Song; Hyungjin Myra Kim; Lillian T Bellfi; Kevin C Chung
Journal:  Plast Reconstr Surg       Date:  2011-03       Impact factor: 4.730

4.  Tattoo pigment in axillary lymph node mimicking calcification of breast cancer.

Authors:  Admire Matsika; Bhuvana Srinivasan; Janet Meryl Gray; Christine Ruth Galbraith
Journal:  BMJ Case Rep       Date:  2013-08-08

5.  Breast MR Imaging: What the Radiologist Needs to Know.

Authors:  Gurpreet S Dhillon; Nick Bell; Daniel T Ginat; Alena Levit; Stamatia Destounis; Avice O'Connell
Journal:  J Clin Imaging Sci       Date:  2011-10-03

6.  Breast MRI: guidelines from the European Society of Breast Imaging.

Authors:  R M Mann; C K Kuhl; K Kinkel; C Boetes
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

7.  Bilateral poly implant prothèse implant rupture: an uncommon presentation.

Authors:  Peter Mallon; François Ganachaud; Caroline Malhaire; Raphael Brunel; Brigitte Sigal-Zafrani; Jean-Guillaume Feron; Benoit Couturaud; Alfred Fitoussi; Fabien Reyal
Journal:  Plast Reconstr Surg Glob Open       Date:  2013-08-07

8.  Study of breast implants mammography examinations for identification of suitable image quality criteria.

Authors:  Cláudia Sá Dos Reis; Isabelle Gremion; Nicole Richli Meystre
Journal:  Insights Imaging       Date:  2020-01-03
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.