Literature DB >> 15250225

Novel bronchofiberscopic catheter spray device allows effective anesthetic spray and sputum suctioning.

Koichiro Kenzaki1, Yukiko Hirose, Masafumi Tamaki, Shoji Sakiyama, Kazuya Kondo, Teruo Mutsuda, Yasumasa Monden.   

Abstract

STUDY
OBJECTIVES: To evaluate how serum lidocaine concentrations (SLC) rise when lidocaine is administered by a Bronchofiberscopic Catheter Spray Device (BCSD), and to demonstrate the effect on the aspiration speed of a substitute for sputum when a catheter spray remains in the channel of the bronchofiberscope (BF).
METHODS: This is a prospective randomized clinical study. After lidocaine ultrasonic nebulizer, the BF was inserted orally. During the procedure patients received 4% lidocaine by two methods. In Group 1, 11 patients received lidocaine by bronchofiberscopic (BF) injection. In Group 2, 15 patients received lidocaine by spraying from the diameter 1.06 mm catheter through the BF channel. SLC were measured at 40 min from onset of nebulization. Separately, we examined how effectively sputum was aspirated through the BF channel with a catheter.
RESULTS: Total lidocaine dose (TLD) is the total dose used for nebulization and for the BF injection or spray. The TLD for Groups 1 and 2 were 698.2+/-162.1 mg (mean+/-SD) and 498.7+/-103.8 mg, respectively (P = 0.03). The SLC for Groups 1 and 2 were 1.28+/-0.72 and 1.48+/-0.70 mg/l, respectively (P = 0.49).
CONCLUSIONS: Using BCSD allows easier in administration of lidocaine and is not associated with a significant increase in SLC in comparison with BF injection. Although sputum aspiration using the BF inserted with our catheter was somewhat slow, we did not feel inconvenient so much. Compared to the conventional method, using BCSD may be preferable for patients and bronchoscopists.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15250225     DOI: 10.1016/j.rmed.2004.01.002

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  3 in total

1.  A novel protective barrier enclosure for performing bronchoscopy.

Authors:  Shinichi Yamamoto; Masayuki Nakayama; Hiroyoshi Tsubochi; Shunsuke Endo
Journal:  Respir Investig       Date:  2020-09-16

2.  Comparison of spray catheter with "spray-as-you-go" technique for airway anesthesia during flexible bronchoscopy - A randomized trial.

Authors:  Kavitha Venkatnarayan; Uma Devaraj; Uma Maheswari Krishnaswamy; Priya Ramachandran; Tinku Thomas; George D'Souza
Journal:  Lung India       Date:  2020 Sep-Oct

3.  Use of Ultrathin Bronchoscope on a Need Basis Improves Diagnostic Yield of Difficult-to-Approach Pulmonary Lesions.

Authors:  Yoichi Nishii; Yuki Nakamura; Kentaro Fujiwara; Kentaro Ito; Tadashi Sakaguchi; Yuta Suzuki; Kazuki Furuhashi; Tetsu Kobayashi; Taro Yasuma; Corina N D'Alessandro-Gabazza; Esteban C Gabazza; Fumihiro Asano; Osamu Taguchi; Osamu Hataji
Journal:  Front Med (Lausanne)       Date:  2020-12-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.