Literature DB >> 15248806

Evaluation of an adaptive directional system in a DSP hearing aid.

Ruth A Bentler1, Jill L Tubbs, Jessica L M Egge, Gregory A Flamme, Andrew B Dittberner.   

Abstract

The effectiveness of an adaptive directional microphone design, as implemented in the Phonak Claro behind-the-ear hearing aid, is evaluated. Participants were fit bilaterally and tested in 2 environments, an anechoic chamber and a moderately reverberant classroom, with the microphones in the fixed (cardioid) setting and the adaptive setting. Five speakers were placed between 110 degrees and 250 degrees azimuth around the listener. Speech-weighted noise was presented from those speakers at an overall level (OAL) of 65 dB (A). Noise was increased by 8 dB from 1 speaker at a time, using 2-s modulation and random assignment, while the output from the other speakers was reduced to maintain the constant OAL. Results of 2 speech perception tasks used as outcome measures indicated that the adaptive system was not able to follow the dominant noise source in the presence of lower level noise sources. Self-report measures obtained after blinded home trials were consistent with laboratory findings that the participants did not perceive this adaptive microphone design to be more effective than the default fixed-microphone option.

Entities:  

Mesh:

Year:  2004        PMID: 15248806     DOI: 10.1044/1059-0889(2004/010)

Source DB:  PubMed          Journal:  Am J Audiol        ISSN: 1059-0889            Impact factor:   1.493


  4 in total

Review 1.  Challenges and recent developments in hearing aids. Part I. Speech understanding in noise, microphone technologies and noise reduction algorithms.

Authors:  King Chung
Journal:  Trends Amplif       Date:  2004

2.  A historical perspective on digital hearing AIDS: how digital technology has changed modern hearing AIDS.

Authors:  Harry Levitt
Journal:  Trends Amplif       Date:  2007-03

3.  Classification of Hearing Aids Into Feature Profiles Using Hierarchical Latent Class Analysis Applied to a Large Dataset of Hearing Aids.

Authors:  Simon Lansbergen; Wouter A Dreschler
Journal:  Ear Hear       Date:  2020 Nov/Dec       Impact factor: 3.570

4.  The minimum monitoring signal-to-noise ratio for off-axis signals and its implications for directional hearing aids.

Authors:  Alan W Archer-Boyd; Jack A Holman; W Owen Brimijoin
Journal:  Hear Res       Date:  2017-11-27       Impact factor: 3.208