Literature DB >> 1524031

Aerosol penetration through filtering facepieces and respirator cartridges.

C C Chen1, M Lehtimäki, K Willeke.   

Abstract

Air-purifying respirators must be certified following the National Institute for Occupational Safety and Health (NIOSH) filter test criteria (30 CFR 11). The criteria specify a range for the mean particle size and the measure of spread permissible for the test aerosol. The authors' experiments have shown that aerosol penetration as a function of particle size differs considerably among certified respirators of the same type. Filtering facepieces (disposable respirators) and cartridges of the dust-mist, dust-mist-fume, and high-efficiency particulate air type were tested. The respirators were sealed to mannequins in a test chamber. The aerosol concentrations inside and outside the respirator were measured by an aerodynamic particle sizer and a laser aerosol spectrometer over a particle size range of 0.1 to 15 microns. Five flow rates ranging from 5 to 100 L/min were used to study flow dependency. The aerosol penetration through the filters is presented as a function of particle size. Aerosol penetration and pressure drop are combined to express the performance of each filter in terms of "quality factor." Under the same test conditions, the quality factor of one respirator may be as much as 6.6 times more than that of another respirator of the same type. The filter quality factor has a greater aerosol size dependency as airflow and aerosol size increase. In general, cartridges have a larger surface area than filtering facepieces but not necessarily lower filter penetration or higher filter quality.(ABSTRACT TRUNCATED AT 250 WORDS)

Mesh:

Substances:

Year:  1992        PMID: 1524031     DOI: 10.1080/15298669291360166

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  4 in total

1.  Criteria for the collection of useful respirator performance data in the workplace.

Authors:  Larry Janssen; Ziqing Zhuang; Ronald Shaffer
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

2.  Dry heat sterilization as a method to recycle N95 respirator masks: The importance of fit.

Authors:  John G Yuen; Amy C Marshilok; Peter Todd Benziger; Shan Yan; Jeronimo Cello; Chavis A Stackhouse; Kim Kisslinger; David C Bock; Esther S Takeuchi; Kenneth J Takeuchi; Lei Wang; Sruthi Babu; Glen Itzkowitz; David Thanassi; Daniel A Knopf; Kenneth R Shroyer
Journal:  PLoS One       Date:  2022-01-05       Impact factor: 3.240

3.  Filter performance of n99 and n95 facepiece respirators against viruses and ultrafine particles.

Authors:  Robert M Eninger; Takeshi Honda; Atin Adhikari; Helvi Heinonen-Tanski; Tiina Reponen; Sergey A Grinshpun
Journal:  Ann Occup Hyg       Date:  2008-05-13

Review 4.  Respiratory protection against bioaerosols: literature review and research needs.

Authors:  Appavoo Rengasamy; Ziqing Zhuang; Roland Berryann
Journal:  Am J Infect Control       Date:  2004-10       Impact factor: 2.918

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.