Literature DB >> 15239202

Effect of frequency boundary assignment on vowel recognition with the Nucleus 24 ACE speech coding strategy.

Marios S Fourakis1, John W Hawks, Laura K Holden, Margaret W Skinner, Timothy A Holden.   

Abstract

Two speech processor programs (MAPs) differing only in electrode frequency boundary assignments were created for each of eight Nucleus 24 Cochlear Implant recipients. The default MAPs used typical frequency boundaries, and the experimental MAPs reassigned one additional electrode to vowel formant regions. Four objective speech tests and a questionnaire were used to evaluate speech recognition with the two MAPs. Results for the closed-set vowel test and the formant discrimination test showed small but significant improvement in scores with the experimental MAP. Differences for the Consonant-Vowel Nucleus-Consonant word test and closed-set consonant test were nonsignificant. Feature analysis revealed no significant differences in information transmission. Seven of the eight subjects preferred the experimental MAP, reporting louder, crisper, and clearer sound. The results suggest that Nucleus 24 recipients should be given an opportunity to compare a MAP that assigns more electrodes in vowel formant regions with the default MAP to determine which provides the most benefit in everyday life.

Mesh:

Year:  2004        PMID: 15239202     DOI: 10.3766/jaaa.15.4.3

Source DB:  PubMed          Journal:  J Am Acad Audiol        ISSN: 1050-0545            Impact factor:   1.664


  5 in total

1.  A glimpsing account for the benefit of simulated combined acoustic and electric hearing.

Authors:  Ning Li; Philipos C Loizou
Journal:  J Acoust Soc Am       Date:  2008-04       Impact factor: 1.840

2.  The Impact of Auditory Spectral Resolution on Listening Effort Revealed by Pupil Dilation.

Authors:  Matthew B Winn; Jan R Edwards; Ruth Y Litovsky
Journal:  Ear Hear       Date:  2015 Jul-Aug       Impact factor: 3.570

3.  Benefits of preserving stationary and time-varying formant structure in alternative representations of speech: implications for cochlear implants.

Authors:  Susan Nittrouer; Joanna H Lowenstein; Taylor Wucinich; Eric Tarr
Journal:  J Acoust Soc Am       Date:  2014-10       Impact factor: 1.840

4.  Use of an adaptive-bandwidth protocol to measure importance functions for simulated cochlear implant frequency channels.

Authors:  Nathaniel A Whitmal; Kristina DeRoy
Journal:  J Acoust Soc Am       Date:  2012-02       Impact factor: 2.482

5.  Investigating the use of a Gammatone filterbank for a cochlear implant coding strategy.

Authors:  Sonia Tabibi; Andrea Kegel; Wai Kong Lai; Norbert Dillier
Journal:  J Neurosci Methods       Date:  2016-12-08       Impact factor: 2.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.