Literature DB >> 15238401

Assessment of effective dose from concomitant exposures required in verification of the target volume in radiotherapy.

S P Waddington1, A L McKenzie.   

Abstract

The requirement of the Ionising Radiation (Medical Exposure) Regulation 2000 [IR(ME)R] of justifying all exposures to ionizing radiation includes those from radiotherapy double exposure portal images resulting in exposure to normal tissues outside the treatment volume. Typical effective doses were calculated for a range of common sites using CT data to outline those parts of specific organs subject to concomitant radiation and generate dose-volume histograms. The product of the mean dose and the relative probability of inducing a fatal cancer in specific organs was used to determine a representative total effective dose in mSv per monitor unit for each site. A table of representative effective doses, ranging from 0.32 mSv to 2.56 mSv per monitor unit, was produced, which may be used to monitor cumulative effective doses of individual patients from double exposure portal images, in addition to those received from localization procedures.

Entities:  

Mesh:

Year:  2004        PMID: 15238401     DOI: 10.1259/bjr/67235257

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

Authors:  Kyle McMillan; Michael McNitt-Gray; Dan Ruan
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

Review 2.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

3.  Dose optimisation during imaging in radiotherapy.

Authors:  P Ravindran
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

4.  Examining the frequency and concomitant dose of geometric verification imaging for patients undergoing proton beam therapy for ocular tumours; an audit of current clinical practice.

Authors:  Kate Shrewsbury-Gee; Daniel Kelly; Mike Kirby
Journal:  BJR Open       Date:  2021-07-05

5.  Reducing excess radiation from portal imaging of pediatric brain tumors.

Authors:  Moses Tam; Maya Mathew; Christine J Hitchen; Ashwatha Narayana
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

6.  A software tool of digital tomosynthesis application for patient positioning in radiotherapy.

Authors:  Hui Yan; Jian-Rong Dai
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.