Literature DB >> 15237068

Glycemic patterns detected by continuous subcutaneous glucose sensing in children and adolescents with type 1 diabetes mellitus treated by multiple daily injections vs continuous subcutaneous insulin infusion.

Naomi Weintrob1, Amir Schechter, Hadassa Benzaquen, Shlomit Shalitin, Pearl Lilos, Avinoam Galatzer, Moshe Phillip.   

Abstract

OBJECTIVE: To compare glycemic patterns by mode of therapy in children with type 1 diabetes mellitus using the Continuous Glucose Monitoring System (CGMS).
DESIGN: Open randomized crossover comparing 3(1/2) months of multiple daily injections (MDI) and continuous subcutaneous insulin infusion (CSII).
SETTING: Tertiary care, university-affiliated medical center. Patients Twenty-three children and adolescents with type 1 diabetes mellitus.
INTERVENTIONS: The CGMS was applied for 72 hours after 1 month and at the end of each study arm. MAIN OUTCOME MEASURES: Hemoglobin A(1c) levels and glucose level profiles were compared between the 2 study arms and the 2 sensor applications for each arm.
RESULTS: The arms were similar for mean (SD) hemoglobin A(1c) levels (CSII, 8.0% [0.8%]; and MDI, 8.2% [0.8%]) and glucose levels. Areas under the curve were significantly larger during MDI for nocturnal and 24-hour hypoglycemia (P =.01 and.04, respectively) and for postprandial hypoglycemia and hyperglycemia (P =.03 and.05, respectively). The rate of hyperglycemia increased during CSII (P =.03), but 24-hour duration and area under the curve for hyperglycemia were similar. Compared with the first CGMS reading in each arm, the second had a longer mean duration of postprandial within-target glucose levels (P =.04), tendency for lower rate of diurnal hypoglycemic events (P =.1), shorter duration of nocturnal hypoglycemia (P =.05), and smaller 24-hour area under the curve for hypoglycemia (P =.04).
CONCLUSIONS: Intensive treatment with CSII seemed to be associated with slightly better prebreakfast, postprandial, and within-target glucose profiles than MDI, as well as a smaller area under the curve for hypoglycemia. Lower hypoglycemia-related variables in the second sensor reading in each arm indicate that the CGMS may serve as an educational tool to decrease the rate and magnitude of hypoglycemia.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15237068     DOI: 10.1001/archpedi.158.7.677

Source DB:  PubMed          Journal:  Arch Pediatr Adolesc Med        ISSN: 1072-4710


  12 in total

Review 1.  Hypoglycemia in critically ill children.

Authors:  E Vincent S Faustino; Eliotte L Hirshberg; Clifford W Bogue
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

2.  Benefits of blinded continuous glucose monitoring during a randomized clinical trial.

Authors:  Douglas Muchmore; Melissa Sharp; Daniel Vaughn
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

3.  A review of current evidence with continuous glucose monitoring in patients with diabetes.

Authors:  Christophe De Block; Begoña Manuel-y-Keenoy; Luc Van Gaal
Journal:  J Diabetes Sci Technol       Date:  2008-07

Review 4.  Continuous glucose monitoring in insulin-treated patients in non-ICU settings.

Authors:  Ana Maria Gomez; Guillermo E Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2014-08-13

Review 5.  Continuous subcutaneous insulin infusion versus multiple daily injections in individuals with type 1 diabetes: a systematic review and meta-analysis.

Authors:  Khalid Benkhadra; Fares Alahdab; Shrikant U Tamhane; Rozalina G McCoy; Larry J Prokop; Mohammad Hassan Murad
Journal:  Endocrine       Date:  2016-08-01       Impact factor: 3.633

6.  The effect of socioeconomic deprivation on efficacy of continuous subcutaneous insulin infusion: a retrospective paediatric case-controlled survey.

Authors:  Senthil Senniappan; Paul Hine; Wing Tang; Judith Campbell; Mark Bone; Vengudi Sankar; Mark Robinson; Claire Smith; Chris Cooper; Rakesh Amin
Journal:  Eur J Pediatr       Date:  2011-05-19       Impact factor: 3.183

7.  Effects of pulsatile subcutaneous injections of insulin lispro on plasma insulin concentration levels.

Authors:  Alice Chan; Marc D Breton; Boris P Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2008-09

Review 8.  Comparative analysis of the efficacy of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes mellitus.

Authors:  Baraka Floyd; Prakash Chandra; Stephanie Hall; Christopher Phillips; Ernest Alema-Mensah; Gregory Strayhorn; Elizabeth O Ofili; Guillermo E Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

9.  Evaluation of the utility of a glycemic pattern identification system.

Authors:  Erik A Otto; Vinay Tannan
Journal:  J Diabetes Sci Technol       Date:  2014-05-12

10.  The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System.

Authors:  Young Ha Baek; Heung Yong Jin; Kyung Ae Lee; Seon Mee Kang; Woong Ji Kim; Min Gul Kim; Ji Hyun Park; Soo Wan Chae; Hong Sun Baek; Tae Sun Park
Journal:  Korean Diabetes J       Date:  2010-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.