A new technique was developed to increase the signal-to-noise ratio (SNR) in displacement encoding with stimulated echoes (DENSE) MRI. This signal-averaged DENSE (sav-DENSE) technique is based on the SNR advantage of extracting a pair of DENSE images with uncorrelated noise from the complex complementary spatial modulation of the magnetization image, and combining them during image reconstruction. Eleven healthy volunteers were imaged at three short-axis locations with the use of sav-DENSE, cine DENSE, and myocardial tagging pulse sequences. In this study, sav-DENSE increased the SNR by 15-34% as compared to cine DENSE. Circumferential strain values measured by sav-DENSE and myocardial tagging were strongly correlated (slope = 0.95, intercept = -0.02, R = 0.92) and within the 95% limits of agreement. The breath-hold sav-DENSE technique yielded relatively accurate and precise quantification of 2D intramyocardial function, with a 40.2-ms temporal resolution and a 3.5 x 3.5 mm2 spatial resolution. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15236385     DOI: 10.1002/mrm.20109

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

Review 1.  Role of cardiac MRI and nuclear imaging in cardiac resynchronization therapy.

Authors:  Niti R Aggarwal; Matthew W Martinez; Bernard J Gersh; Panithaya Chareonthaitawee
Journal:  Nat Rev Cardiol       Date:  2009-11-03       Impact factor: 32.419

Review 2.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

Review 3.  Nonechocardiographic imaging in evaluation for cardiac resynchronization therapy.

Authors:  Wael AlJaroudi; Ji Chen; Wael A Jaber; Steven G Lloyd; Manuel D Cerqueira; Thomas Marwick
Journal:  Circ Cardiovasc Imaging       Date:  2011-05       Impact factor: 7.792

4.  Effect of through-plane motion on left ventricular rotation: a study using slice-following harmonic phase imaging.

Authors:  David Brotman; Ziheng Zhang; Smita Sampath
Journal:  Magn Reson Med       Date:  2012-06-14       Impact factor: 4.668

Review 5.  Stress Cardiac Magnetic Resonance Myocardial Perfusion Imaging: JACC Review Topic of the Week.

Authors:  Amit R Patel; Michael Salerno; Raymond Y Kwong; Amita Singh; Bobak Heydari; Christopher M Kramer
Journal:  J Am Coll Cardiol       Date:  2021-10-19       Impact factor: 27.203

6.  Strain and torsion quantification in mouse hearts under dobutamine stimulation using 2D multiphase MR DENSE.

Authors:  Jia Zhong; Xin Yu
Journal:  Magn Reson Med       Date:  2010-08-25       Impact factor: 4.668

7.  Numerical and in vivo validation of fast cine displacement-encoded with stimulated echoes (DENSE) MRI for quantification of regional cardiac function.

Authors:  Li Feng; Robert Donnino; James Babb; Leon Axel; Daniel Kim
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

8.  Accuracy of cardiac-induced brain motion measurement using displacement-encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI): A phantom study.

Authors:  Blaise Simplice Talla Nwotchouang; Maggie S Eppelheimer; Dipankar Biswas; Soroush Heidari Pahlavian; Xiaodong Zhong; John N Oshinski; Daniel L Barrow; Rouzbeh Amini; Francis Loth
Journal:  Magn Reson Med       Date:  2020-08-31       Impact factor: 4.668

9.  Validation of in vivo 2D displacements from spiral cine DENSE at 3T.

Authors:  Gregory J Wehner; Jonathan D Suever; Christopher M Haggerty; Linyuan Jing; David K Powell; Sean M Hamlet; Jonathan D Grabau; Walter Dimitri Mojsejenko; Xiaodong Zhong; Frederick H Epstein; Brandon K Fornwalt
Journal:  J Cardiovasc Magn Reson       Date:  2015-01-30       Impact factor: 5.364

10.  A Novel Method for Estimating Myocardial Strain: Assessment of Deformation Tracking Against Reference Magnetic Resonance Methods in Healthy Volunteers.

Authors:  Kenneth Mangion; Hao Gao; Christie McComb; David Carrick; Guillaume Clerfond; Xiaodong Zhong; Xiaoyu Luo; Caroline E Haig; Colin Berry
Journal:  Sci Rep       Date:  2016-12-12       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.