Literature DB >> 15234459

Cervical spinal cord MTR histogram analysis in multiple sclerosis using a 3D acquisition and a B-spline active surface segmentation technique.

S J Hickman1, A Hadjiprocopis, O Coulon, D H Miller, G J Barker.   

Abstract

The application of a three-dimensional magnetization transfer (MT) sequence and B-spline active surface segmentation method to produce MT histograms of the cervical spinal cord in a pilot study of controls and multiple sclerosis (MS) patients is presented. Subjects' cervical spinal cords were imaged with (a) a volume-acquired inversion-prepared fast spoiled gradient echo sequence and (b) a volume-acquired noninversion-prepared fast spoiled gradient echo MT sequence. The images were segmented using the B spline active surface technique and MT histograms were produced from the MT images. The method was sensitive enough to detect differences between seven MS patients and 10 controls in mean MT ratio (42.4 pu versus 44.0 pu, p = 0.03) and peak location (45.2 versus 46.8, p = 0.03). The spinal cord volumes obtained from the two sequences were associated with each other (parameter estimate 0.972, 95% confidence intervals 0.742, 1.202, p < 0.001).

Entities:  

Mesh:

Year:  2004        PMID: 15234459     DOI: 10.1016/j.mri.2004.01.056

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  12 in total

Review 1.  Magnetic resonance imaging of myelin.

Authors:  Cornelia Laule; Irene M Vavasour; Shannon H Kolind; David K B Li; Tony L Traboulsee; G R Wayne Moore; Alex L MacKay
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

2.  Rapid, high-resolution quantitative magnetization transfer MRI of the human spinal cord.

Authors:  Alex K Smith; Richard D Dortch; Lindsey M Dethrage; Seth A Smith
Journal:  Neuroimage       Date:  2014-03-13       Impact factor: 6.556

Review 3.  Future Brain and Spinal Cord Volumetric Imaging in the Clinic for Monitoring Treatment Response in MS.

Authors:  Tim Sinnecker; Cristina Granziera; Jens Wuerfel; Regina Schlaeger
Journal:  Curr Treat Options Neurol       Date:  2018-04-20       Impact factor: 3.598

4.  Reliable and fast volumetry of the lumbar spinal cord using cord image analyser (Cordial).

Authors:  Charidimos Tsagkas; Anna Altermatt; Ulrike Bonati; Simon Pezold; Julia Reinhard; Michael Amann; Philippe Cattin; Jens Wuerfel; Dirk Fischer; Katrin Parmar; Arne Fischmann
Journal:  Eur Radiol       Date:  2018-04-30       Impact factor: 5.315

Review 5.  Multiple sclerosis: the role of MR imaging.

Authors:  Y Ge
Journal:  AJNR Am J Neuroradiol       Date:  2006 Jun-Jul       Impact factor: 3.825

Review 6.  Segmentation of the human spinal cord.

Authors:  Benjamin De Leener; Manuel Taso; Julien Cohen-Adad; Virginie Callot
Journal:  MAGMA       Date:  2016-01-02       Impact factor: 2.310

7.  Reliable volumetry of the cervical spinal cord in MS patient follow-up data with cord image analyzer (Cordial).

Authors:  Michael Amann; Simon Pezold; Yvonne Naegelin; Ketut Fundana; Michaela Andělová; Katrin Weier; Christoph Stippich; Ludwig Kappos; Ernst-Wilhelm Radue; Philippe Cattin; Till Sprenger
Journal:  J Neurol       Date:  2016-05-09       Impact factor: 4.849

8.  Fast and accurate semi-automated segmentation method of spinal cord MR images at 3T applied to the construction of a cervical spinal cord template.

Authors:  Mohamed-Mounir El Mendili; Raphaël Chen; Brice Tiret; Noémie Villard; Stéphanie Trunet; Mélanie Pélégrini-Issac; Stéphane Lehéricy; Pierre-François Pradat; Habib Benali
Journal:  PLoS One       Date:  2015-03-27       Impact factor: 3.240

Review 9.  Imaging outcomes for trials of remyelination in multiple sclerosis.

Authors:  Shahrukh Mallik; Rebecca S Samson; Claudia A M Wheeler-Kingshott; David H Miller
Journal:  J Neurol Neurosurg Psychiatry       Date:  2014-04-25       Impact factor: 10.154

10.  Fully automated grey and white matter spinal cord segmentation.

Authors:  Ferran Prados; M Jorge Cardoso; Marios C Yiannakas; Luke R Hoy; Elisa Tebaldi; Hugh Kearney; Martina D Liechti; David H Miller; Olga Ciccarelli; Claudia A M Gandini Wheeler-Kingshott; Sebastien Ourselin
Journal:  Sci Rep       Date:  2016-10-27       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.