Fast multi-planar gradient echo MR imaging: impact of variation in pulse sequence parameters on image quality and artifacts.

Tao Li1, Scott A Mirowitz.   

Abstract

The purpose of this investigation was to quantitatively evaluate the practical impact of alteration of key imaging parameters on image quality and artifacts in fast multi-planar gradient echo (GRE) pulse sequences. These include multi-planar GRASS (MPGR) and fast multi-planar spoiled GRASS (FMPSPGR). We developed a composite phantom with different T(1) and T(2) values comprising the range of common biological tissues, which was also subjected to periodic motion in order to evaluate motion effects. Magnetic resonance imaging was performed on a GE Signa 1.5-T system. Experimental variations in key parameters included excitation flip angle (FL), echo time (TE), repetition time (TR), and receive bandwidth (BW). Quantitative analysis consisted of signal-to-noise-ratio (SNR) and contrast (CN), image nonuniformity (NU), full-width-at-half-maximum (FWHM) (i.e., blurring or geometric distortion), and ghosting ratio (GR). We found that flip angle, TE, and TR play particularly critical roles in determining image signal, homogeneity, and ghosting artifact with these sequences. Optimum clinical application of these pulse sequences requires careful attention to these imaging parameters and to their complex interactions.

Entities:  

Mesh:

Year:  2004        PMID: 15234449     DOI: 10.1016/j.mri.2004.01.051

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

1.  Influence of pulse sequence parameters at 1.5 T and 3.0 T on MRI artefacts produced by metal-ceramic restorations.

Authors:  A R G Cortes; R Abdala-Junior; M Weber; E S Arita; J L Ackerman
Journal:  Dentomaxillofac Radiol       Date:  2015-06-18       Impact factor: 2.419

2.  High-resolution morphological and biochemical imaging of articular cartilage of the ankle joint at 3.0 T using a new dedicated phased array coil: in vivo reproducibility study.

Authors:  Goetz H Welsch; Tallal C Mamisch; Michael Weber; Wilhelm Horger; Klaus Bohndorf; Siegfried Trattnig
Journal:  Skeletal Radiol       Date:  2008-06       Impact factor: 2.199

3.  A voxel-based morphometry comparison of the 3.0T ADNI-1 and ADNI-2 volumetric MRI protocols.

Authors:  Simon Brunton; Cerisse Gunasinghe; Nigel Jones; Matthew J Kempton; Eric Westman; Andrew Simmons
Journal:  Int J Geriatr Psychiatry       Date:  2014-08-04       Impact factor: 3.485

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.