Literature DB >> 15234447

Aspects on the accuracy of cerebral perfusion parameters obtained by dynamic susceptibility contrast MRI: a simulation study.

Linda Knutsson1, Freddy Ståhlberg, Ronnie Wirestam.   

Abstract

Several studies have indicated that deconvolution based on singular value decomposition (SVD) is a robust concept for retrieval of cerebral blood flow in dynamic susceptibility contrast (DSC) MRI. However, the behavior of the technique under typical experimental conditions has not been completely investigated. In the present study, cerebral perfusion was simulated using different temporal resolutions, different signal-to-noise ratios (S/Ns), different shapes of the arterial input function (AIF), different signal drops, and different cut-off levels in the SVD deconvolution. Using Zierler's area-to-height relationship in combination with the central volume theorem, calculations of regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF), and regional mean transit time (rMTT) were accomplished, based on simulated DSC-MRI signal curves corresponding to artery, gray matter (GM), white matter (WM), and ischemic tissue. Gaussian noise was added to the noise-free signal curves to generate different S/Ns. We studied image time intervals of 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 s, as well as different degrees of signal decrease. The singular-value threshold in the SVD procedure and the shape of the AIF were also varied. Increased rCBF was seen when noise was added, especially for rCBF in WM at the larger image time intervals. The rCBF showed large standard deviations using a low threshold value. A prolonged time interval led to a lower absolute value of rCBF both in GM and WM, and a low/broad AIF also underestimated the rCBF. When a larger maximal signal decrease was assumed, smaller standard deviations were observed. No systematic change of the average rCBV was observed with increasing noise or with increasing image time interval. At S/N = 40, a low cut-off value resulted in an rCBF that was closer to the true value. Furthermore, at low S/N it was difficult to differentiate ischemic tissue from WM.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15234447     DOI: 10.1016/j.mri.2003.12.002

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  18 in total

1.  ASFNR recommendations for clinical performance of MR dynamic susceptibility contrast perfusion imaging of the brain.

Authors:  K Welker; J Boxerman; A Kalnin; T Kaufmann; M Shiroishi; M Wintermark
Journal:  AJNR Am J Neuroradiol       Date:  2015-04-23       Impact factor: 3.825

2.  A fully automated method for quantitative cerebral hemodynamic analysis using DSC-MRI.

Authors:  Atle Bjørnerud; Kyrre E Emblem
Journal:  J Cereb Blood Flow Metab       Date:  2010-01-20       Impact factor: 6.200

Review 3.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

4.  Validating a local Arterial Input Function method for improved perfusion quantification in stroke.

Authors:  Lisa Willats; Soren Christensen; Henry K Ma; Geoffrey A Donnan; Alan Connelly; Fernando Calamante
Journal:  J Cereb Blood Flow Metab       Date:  2011-06-01       Impact factor: 6.200

5.  Model-free quantification of dynamic PET data using nonparametric deconvolution.

Authors:  Francesca Zanderigo; Ramin V Parsey; R Todd Ogden
Journal:  J Cereb Blood Flow Metab       Date:  2015-04-15       Impact factor: 6.200

6.  Influence of blood/tissue differences in contrast agent relaxivity on tracer-based MR perfusion measurements.

Authors:  Arvid Morell; Fredrik Lennmyr; Ove Jonsson; Thomas Tovedal; Jean Pettersson; Jonas Bergquist; Vitas Zemgulis; Gunnar Myrdal Einarsson; Stefan Thelin; Håkan Ahlström; Atle Bjørnerud
Journal:  MAGMA       Date:  2014-06-28       Impact factor: 2.310

7.  Slice-accelerated gradient-echo echo planar imaging dynamic susceptibility contrast-enhanced MRI with blipped CAIPI: effect of increasing temporal resolution.

Authors:  Tomohiro Takamura; Masaaki Hori; Koji Kamagata; Kanako K Kumamaru; Ryusuke Irie; Akifumi Hagiwara; Nozomi Hamasaki; Shigeki Aoki
Journal:  Jpn J Radiol       Date:  2017-10-31       Impact factor: 2.374

8.  Quantification of intracranial arterial blood flow using noncontrast enhanced 4D dynamic MR angiography.

Authors:  Xingfeng Shao; Ziwei Zhao; Jonathan Russin; Arun Amar; Nerses Sanossian; Danny Jj Wang; Lirong Yan
Journal:  Magn Reson Med       Date:  2019-03-07       Impact factor: 4.668

9.  Cerebral perfusion changes in migraineurs: a voxelwise comparison of interictal dynamic susceptibility contrast MRI measurements.

Authors:  Enrico B Arkink; Egbert J W Bleeker; Nicole Schmitz; Guus G Schoonman; Ona Wu; Michel D Ferrari; Mark A van Buchem; Matthias J P van Osch; Mark C Kruit
Journal:  Cephalalgia       Date:  2012-01-30       Impact factor: 6.292

10.  Cerebral perfusion disturbances in chronic mild traumatic brain injury correlate with psychoemotional outcomes.

Authors:  Efrosini Papadaki; Eleftherios Kavroulakis; Katina Manolitsi; Dimitrios Makrakis; Emmanouil Papastefanakis; Pelagia Tsagaraki; Styliani Papadopoulou; Alexandros Zampetakis; Margarita Malliou; Antonios Vakis; Panagiotis Simos
Journal:  Brain Imaging Behav       Date:  2021-06       Impact factor: 3.978

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.