Is defibrillation testing required for defibrillator implantation?

S Adam Strickberger1, George J Klein.   

Abstract

The assessment of defibrillation (DFT) efficacy has long been the standard of care during defibrillator implantation. To ensure an acceptable DFT safety margin, early defibrillator systems frequently required that the shock polarity and the location, type, or number of electrodes had to be altered. Advances in defibrillator and lead technology have resulted in lower and more consistent DFT thresholds in the range of 10 J, with an infrequent requirement to modify the DFT system. Yet, one can make an argument for and against continuation of DFT testing at the time of defibrillator implantation. The goal of this paper is to address both the data that do support and the data that do not support continuation of DFT testing at the time of device implantation. Scientifically, DFT testing should be abandoned only when prospective evidence demonstrates that defibrillator implantation without testing is as safe and has the same mortality benefits as implantation with testing. The most attractive aspect of eliminating DFT efficacy testing is that more patients may have the opportunity to be treated with this life-saving therapy. Perhaps there are alternative strategies to improve accessibility to defibrillator therapy without possibly eroding its effectiveness. In the end, will lives be saved or lost if we discontinue DFT efficacy testing and lower the barriers to implantable defibrillator therapy?

Entities:  

Mesh:

Year:  2004        PMID: 15234413     DOI: 10.1016/j.jacc.2003.11.068

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  12 in total

1.  Shock or no shock - a question of philosophy or should intraoperative implantable cardioverter defibrillator testing be recommended?

Authors:  Andreas Keyser; Michael K Hilker; Sebastian Schmidt; Christian von Bary; Wolfgang Zink; Michael Ried; Christof Schmid; Claudius Diez
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-12-07

2.  ICD implantation without intraoperative testing does not increase the rate of system modifications and does not impair defibrillation efficacy tested in follow-up.

Authors:  Dirk Bastian; Stefan Kracker; Matthias Pauschinger; Konrad Göhl
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-06-07

3.  Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention.

Authors:  Sachin Kumar Amruthlal Jain; Hamid Ghanbari; Rayan Hourani; Timothy R Larsen; Marcos Daccarett; Christian Machado
Journal:  J Interv Card Electrophysiol       Date:  2013-01-20       Impact factor: 1.900

4.  The relationship between defibrillation threshold and total mortality.

Authors:  Jason C Rubenstein; Michael H Kim; Fred Morady; S Adam Strickberger
Journal:  J Interv Card Electrophysiol       Date:  2013-10-22       Impact factor: 1.900

5.  Defibrillation Testing During Defibrillator Implantation.

Authors:  Dietmar Bänsch
Journal:  Arrhythm Electrophysiol Rev       Date:  2012-09

6.  Contemporary rates and outcomes of single- vs. dual-coil implantable cardioverter defibrillator lead implantation: data from the Israeli ICD Registry.

Authors:  Eran Leshem; Mahmoud Suleiman; Avishag Laish-Farkash; Yuval Konstantino; Michael Glikson; Alon Barsheshet; Ilan Goldenberg; Yoav Michowitz
Journal:  Europace       Date:  2017-09-01       Impact factor: 5.214

7.  High defibrillation threshold: the science, signs and solutions.

Authors:  Sony Jacob; Victorio Pidlaoan; Jaspreet Singh; Aditya Bharadwaj; Mehul B Patel; Antonio Carrillo
Journal:  Indian Pacing Electrophysiol J       Date:  2010-01-07

8.  Intraoperative defibrillation threshold testing and postoperative long-term efficacy of cardioverter-defibrillator implantation.

Authors:  Tianyi Gan; Xiaozhi Cao; Zhang Yu; Baopeng Tang; Jinxin Li; Guojun Xu; Xianhui Zhou; Yanyi Zhang; Yaodong Li; Jianghua Zhang
Journal:  Exp Ther Med       Date:  2012-11-05       Impact factor: 2.447

9.  Significance of intraoperative testing in right-sided implantable cardioverter-defibrillators.

Authors:  Andreas Keyser; Michael K Hilker; Ekrem Ucer; Sigrid Wittmann; Christof Schmid; Claudius Diez
Journal:  J Cardiothorac Surg       Date:  2013-04-11       Impact factor: 1.637

10.  Defibrillation testing of the implantable cardioverter defibrillator: when, how, and by whom?

Authors:  Luis A Pires
Journal:  Indian Pacing Electrophysiol J       Date:  2007-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.