Minimum scan speeds for suppression of motion artifacts in CT.

C J Ritchie1, J D Godwin, C R Crawford, W Stanford, H Anno, Y Kim.   

Abstract

Cardiac and ventilatory motions cause artifacts at chest computed tomography (CT). To determine how short the scan times on third-generation units must be to avoid such artifacts, motion was measured with fast and ultrafast CT scans. Minimum detectable motion was then determined. The longest scan time that avoided a barely perceptible artifact was calculated by dividing the minimum detectable motion by the peak physiologic velocity. The posterior left ventricular wall moved at a maximum velocity of 52.5 mm/sec, necessitating a scan time of 19.1 msec or less to avoid artifact. Lung vessels near the heart moved at 40.5 mm/sec for a scan time of 24.7 msec or less. During quiet breathing, pulmonary vessels moved at 10.7 mm/sec for a scan time of 93.5 msec or less. The authors conclude that the shortest scan time on third-generation units (0.6 second) cannot prevent all artifacts arising from motion in the chest. Even ultrafast scan times (50 msec) are not short enough to eliminate artifacts on these units. Thus, reduction of motion artifacts will require techniques other than fast scanning.

Mesh:

Year:  1992        PMID: 1523332     DOI: 10.1148/radiology.185.1.1523332

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  28 in total

1.  Evaluation of right ventricular volume and mass using retrospective ECG-gated cardiac multidetector computed tomography: comparison with first-pass radionuclide angiography.

Authors:  Tae Hoon Kim; Young Hoon Ryu; Jin Hur; Sang Jin Kim; Hyun Soo Kim; Byoung Wook Choi; Young Kim; Hyung Jung Kim
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

2.  Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography.

Authors:  Martin Heuschmid; Julia K Rothfuss; Stephen Schroeder; Michael Fenchel; Norbert Stauder; Christof Burgstahler; Andreas Franow; Ronald S Kuzo; Axel Kuettner; Stephan Miller; Claus D Claussen; Andreas F Kopp
Journal:  Eur Radiol       Date:  2005-10-08       Impact factor: 5.315

Review 3.  Advances in cardiovascular CT imaging: CT technology.

Authors:  Bryan R Westerman
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

4.  Electrocardiography-triggered high-resolution CT for reducing cardiac motion artifact: evaluation of the extent of ground-glass attenuation in patients with idiopathic pulmonary fibrosis.

Authors:  Motoko Nishiura; Takeshi Johkoh; Shuji Yamamoto; Osamu Honda; Takenori Kozuka; Mitsuhiro Koyama; Noriyuki Tomiyama; Seiki Hamada; Takamichi Murakami; Takashi Matsumoto; Yoshifumi Narumi; Hironobu Nakamura
Journal:  Radiat Med       Date:  2007-12-25

5.  Displacement and velocity of the coronary arteries: cardiac and respiratory motion.

Authors:  Guy Shechter; Jon R Resar; Elliot R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  2006-03       Impact factor: 10.048

Review 6.  CT for assessing ventricular remodeling: is it ready for prime time?

Authors:  Gardar Sigurdsson
Journal:  Curr Heart Fail Rep       Date:  2008-03

7.  Novel acoustic radiation force impulse imaging methods for visualization of rapidly moving tissue.

Authors:  Stephen J Hsu; Richard R Bouchard; Douglas M Dumont; Cheng W Ong; Patrick D Wolf; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2009-07       Impact factor: 1.578

8.  The role of acquisition and quantification methods in myocardial blood flow estimability for myocardial perfusion imaging CT.

Authors:  Brendan L Eck; Raymond F Muzic; Jacob Levi; Hao Wu; Rachid Fahmi; Yuemeng Li; Anas Fares; Mani Vembar; Amar Dhanantwari; Hiram G Bezerra; David L Wilson
Journal:  Phys Med Biol       Date:  2018-09-13       Impact factor: 3.609

9.  Evaluation of left atrial volumes using multidetector computed tomography: comparison with echocardiography.

Authors:  Hye Mi Gweon; Sang Jin Kim; Tae Hoon Kim; Sang Min Lee; Yoo Jin Hong; Se-Joong Rim
Journal:  Korean J Radiol       Date:  2010-04-30       Impact factor: 3.500

10.  Comparison of Image Quality and Radiation Dose between High-Pitch Mode and Low-Pitch Mode Spiral Chest CT in Small Uncooperative Children: The Effect of Respiratory Rate.

Authors:  Seong Ho Kim; Young Hun Choi; Hyun-Hae Cho; So Mi Lee; Su-Mi Shin; Jung-Eun Cheon; Woo Sun Kim; In-One Kim
Journal:  Eur Radiol       Date:  2015-08-09       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.