Literature DB >> 15220886

In vivo elbow biomechanical analysis during flexion: three-dimensional motion analysis using magnetic resonance imaging.

Akira Goto1, Hisao Moritomo, Tsuyoshi Murase, Kunihiro Oka, Kazuomi Sugamoto, Takehiro Arimura, Yoshikazu Nakajima, Takaharu Yamazaki, Yoshinobu Sato, Shinichi Tamura, Hideki Yoshikawa, Takahiro Ochi.   

Abstract

The purpose of this article is to evaluate in vivo 3-dimensional kinematics of the elbow joint during elbow flexion. We studied the ulnohumeral and radiohumeral joint noninvasively in 3 elbows in healthy volunteers using a markerless bone registration algorithm. Magnetic resonance images were acquired in 6 positions of elbow flexion. The inferred contact areas on the ulna against the trochlea tended to occur only on the medial facet of the trochlear notch in all of the elbow positions we tested. The inferred contact areas on the radial head against the capitellum occurred on the central depression of the radial head in all of the tested elbow positions except for 135 degrees flexion, where the anterior rim of the radial head articulates with the capitellum.

Entities:  

Mesh:

Year:  2004        PMID: 15220886     DOI: 10.1016/j.jse.2004.01.022

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  15 in total

1.  Experimental determination of the elbow's center of rotation using the VICON™ optoelectronic motion capture system.

Authors:  Elvire Guerre; Pascale Laronde; Jérôme Cussonneau; Christian Fontaine; Guillaume Wavreille
Journal:  Surg Radiol Anat       Date:  2015-11-20       Impact factor: 1.246

2.  In vivo three-dimensional motion analysis of the shoulder joint during internal and external rotation.

Authors:  Hayato Koishi; Akira Goto; Makoto Tanaka; Yasushi Omori; Kazuma Futai; Hideki Yoshikawa; Kazuomi Sugamoto
Journal:  Int Orthop       Date:  2011-06-15       Impact factor: 3.075

3.  Vortical flow in human elbow joints: a three-dimensional computed tomography modeling study.

Authors:  Arnold Adikrishna; Aashay L Kekatpure; Jun Tan; Hyun-Joo Lee; Maria Florencia Deslivia; In-Ho Jeon
Journal:  J Anat       Date:  2014-08-05       Impact factor: 2.610

4.  Distal Humeral Trochlear Geometry Associated With the Spatial Variation of the Dynamic Elbow Flexion Axis.

Authors:  Diyang Zou; Xiangjun Hu; Kai-Nan An; Kerong Dai; Xiaowei Yu; Weihua Gong; Tsung-Yuan Tsai
Journal:  Front Bioeng Biotechnol       Date:  2022-06-24

5.  Subchondral bone density of the radial head measured with subtraction densitometry.

Authors:  T C Koslowsky; K Mader; A Brandenburg; M Hellmich; J Koebke
Journal:  Surg Radiol Anat       Date:  2008-01-09       Impact factor: 1.246

6.  The Effects of Differences in the Morphologies of the Ulnar Collateral Ligament and Common Tendon of the Flexor-Pronator Muscles on Elbow Valgus Braking Function: A Simulation Study.

Authors:  Masahiro Ikezu; Mutsuaki Edama; Takuma Inai; Kanta Matsuzawa; Fumiya Kaneko; Ryo Hirabayashi; Ikuo Kageyama
Journal:  Int J Environ Res Public Health       Date:  2021-02-18       Impact factor: 3.390

7.  Three-Dimensional Morphometric Analysis of the Coracohumeral Distance Using Magnetic Resonance Imaging.

Authors:  Taku Hatta; Nobuyuki Yamamoto; Hirotaka Sano; Yasushi Omori; Kazuomi Sugamoto; Kenji Suzuki; Eiji Itoi
Journal:  Orthop Rev (Pavia)       Date:  2017-03-27

8.  Radiocapitellar joint pressures following transradial amputation increase during elbow motion.

Authors:  Young-Hoon Jo; Bong-Gun Lee; Chang-Hun Lee; Kwang-Hyun Lee; Dong-Hong Kim; Doo-Sup Kim; Sung Jae Kim
Journal:  Sci Rep       Date:  2021-07-06       Impact factor: 4.379

9.  Biomechanics of forearm rotation: force and efficiency of pronator teres.

Authors:  Pere Ibáñez-Gimeno; Ignasi Galtés; Xavier Jordana; Assumpció Malgosa; Joan Manyosa
Journal:  PLoS One       Date:  2014-02-28       Impact factor: 3.240

10.  Effect of Anconeus Muscle Blocking on Elbow Kinematics: Electromyographic, Inertial Sensors and Finite Element Study.

Authors:  Israel Miguel-Andres; Teresa Alonso-Rasgado; Alan Walmsley; Adam C Watts
Journal:  Ann Biomed Eng       Date:  2016-08-29       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.