Literature DB >> 34230504

Radiocapitellar joint pressures following transradial amputation increase during elbow motion.

Young-Hoon Jo1, Bong-Gun Lee2, Chang-Hun Lee2, Kwang-Hyun Lee2, Dong-Hong Kim2, Doo-Sup Kim3, Sung Jae Kim4.   

Abstract

This study aimed to compare the contact area, mean pressure, and peak pressure of the radiocapitellar joint (RCJ) in the upper limb after transradial amputation with those of the normal upper limb during elbow flexion and forearm rotation. Testing was performed using ten fresh-frozen upper limbs, and the transradial amputation was performed 5 cm proximal to the radial styloid process. The specimens were connected to a custom-designed apparatus for testing. A pressure sensor was inserted into the RCJ. The biomechanical indices of the RCJ were measured during elbow flexion and forearm rotation in all specimens. There was no significant difference in the contact area between the normal and transradial amputated upper limbs. However, in the upper limbs after transradial amputation, the mean pressure was higher than that in the normal upper limbs at all positions of elbow flexion and forearm rotation. The peak pressure was significantly higher in the upper limbs after transradial amputation than in the normal upper limbs, and was especially increased during pronation at 45° of elbow flexion. In conclusion, these results could cause cartilage erosion in the RCJ of transradial amputees. Thus, methods to reduce the pressure of the RCJ should be considered when a myoelectric prosthesis is developed.

Entities:  

Year:  2021        PMID: 34230504     DOI: 10.1038/s41598-021-92743-6

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  37 in total

Review 1.  Bionic prosthetic hands: A review of present technology and future aspirations.

Authors:  R G E Clement; K E Bugler; C W Oliver
Journal:  Surgeon       Date:  2011-07-13       Impact factor: 2.392

2.  Characterisation and outcomes of upper extremity amputations.

Authors:  David J Tennent; Joseph C Wenke; Jessica C Rivera; Chad A Krueger
Journal:  Injury       Date:  2014-02-15       Impact factor: 2.586

Review 3.  Upper extremity limb loss: functional restoration from prosthesis and targeted reinnervation to transplantation.

Authors:  Brian T Carlsen; Pat Prigge; Jennifer Peterson
Journal:  J Hand Ther       Date:  2013-12-03       Impact factor: 1.950

Review 4.  Complications following an amputation.

Authors:  Stanley Yoo
Journal:  Phys Med Rehabil Clin N Am       Date:  2014-02       Impact factor: 1.784

5.  Prosthetic usage in major upper extremity amputations.

Authors:  T W Wright; A D Hagen; M B Wood
Journal:  J Hand Surg Am       Date:  1995-07       Impact factor: 2.230

6.  Restoring Natural Forearm Rotation in Transradial Osseointegrated Amputees.

Authors:  Irene Boni; Jason Millenaar; Marco Controzzi; Max Ortiz-Catalan
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2018-11-13       Impact factor: 3.802

Review 7.  The quest for the bionic arm.

Authors:  Douglas T Hutchinson
Journal:  J Am Acad Orthop Surg       Date:  2014-06       Impact factor: 3.020

8.  Adult acquired major upper limb amputation in Norway: prevalence, demographic features and amputation specific features. A population-based survey.

Authors:  Kristin Østlie; Ola H Skjeldal; Beate Garfelt; Per Magnus
Journal:  Disabil Rehabil       Date:  2010-12-22       Impact factor: 3.033

9.  Epidemiology of post-traumatic limb amputation: a National Trauma Databank analysis.

Authors:  Galinos Barmparas; Kenji Inaba; Pedro G R Teixeira; Joseph J Dubose; Michele Criscuoli; Peep Talving; David Plurad; Donald Green; Demetrios Demetriades
Journal:  Am Surg       Date:  2010-11       Impact factor: 0.688

10.  Estimating the prevalence of limb loss in the United States: 2005 to 2050.

Authors:  Kathryn Ziegler-Graham; Ellen J MacKenzie; Patti L Ephraim; Thomas G Travison; Ron Brookmeyer
Journal:  Arch Phys Med Rehabil       Date:  2008-03       Impact factor: 3.966

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.