Literature DB >> 15219019

Continuous, noninvasive monitoring of total hemoglobin concentration by an optoacoustic technique.

Rinat O Esenaliev1, Yuriy Y Petrov, Olaf Hartrumpf, Donald J Deyo, Donald S Prough.   

Abstract

Measurement of total hemoglobin concentration [Hgb] is a blood test that is widely used to evaluate outpatients, hospital inpatients, and surgical patients, especially those undergoing surgery associated with extensive blood loss, rapid fluid administration, and transfusion of packed red blood cells. Current techniques for measurement of [Hgb] are invasive (requiring blood sampling) and cannot provide real-time, continuous monitoring. We propose to use an optoacoustic technique for noninvasive and continuous monitoring of [Hgb]. The high resolution of the optoacoustic technique may provide accurate measurement of [Hgb] by detection and analysis of optoacoustic signals induced by short optical pulses in blood circulating in arteries or veins. We designed, built, and tested in vitro (in both tissue phantoms and in preliminary in vivo experiments) a portable optoacoustic system for the monitoring of [Hgb] in the radial artery. The system includes a nanosecond laser operating in the near-infrared spectral range and a sensitive optoacoustic probe designed to irradiate the radial artery through the skin and detect optoacoustic signals induced in blood. Results of our studies demonstrated that (1) the slope of optoacoustic waves induced in blood in the transmission mode is linearly dependent on [Hgb] in the range from 6.2 to 12.4 g/dl, (2) optoacoustic signals can be detected despite optical attenuation in turbid tissue phantoms with a thickness of 1 cm, and (3) the optoacoustic system detects signals induced in blood circulating in the radial artery. These data suggest that the optoacoustic system can be used for accurate, noninvasive, real-time, and continuous monitoring of [Hgb].

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15219019     DOI: 10.1364/ao.43.003401

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  7 in total

Review 1.  Photoacoustic imaging and characterization of the microvasculature.

Authors:  Song Hu; Lihong V Wang
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

Review 2.  Optoacoustic imaging in endocrinology and metabolism.

Authors:  Angelos Karlas; Miguel A Pleitez; Juan Aguirre; Vasilis Ntziachristos
Journal:  Nat Rev Endocrinol       Date:  2021-04-19       Impact factor: 43.330

3.  Measurement of cardiac output by use of noninvasively measured transient hemodilution curves with photoacoustic technology.

Authors:  Dongyel Kang; Qiaojian Huang; Youzhi Li
Journal:  Biomed Opt Express       Date:  2014-04-07       Impact factor: 3.732

4.  3-D photoacoustic and pulse echo imaging of prostate tumor progression in the mouse window chamber.

Authors:  Daniel R Bauer; Ragnar Olafsson; Leonardo G Montilla; Russell S Witte
Journal:  J Biomed Opt       Date:  2011-02       Impact factor: 3.170

Review 5.  Optoacoustic Monitoring of Physiologic Variables.

Authors:  Rinat O Esenaliev
Journal:  Front Physiol       Date:  2017-12-12       Impact factor: 4.566

6.  Optoacoustic diagnostic modality: from idea to clinical studies with highly compact laser diode-based systems.

Authors:  Rinat O Esenaliev
Journal:  J Biomed Opt       Date:  2017-09-01       Impact factor: 3.170

7.  Prediction of plasma hemoglobin concentration by near-infrared spectroscopy.

Authors:  Younsuk Lee; Sangseok Lee; Junyong In; Seung-Hyun Chung; Jun Heum Yon
Journal:  J Korean Med Sci       Date:  2008-08       Impact factor: 2.153

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.