Literature DB >> 15218455

Percutaneous repair of abdominal aortic aneurysm.

Mark D Morasch1, Melina R Kibbe, Mary E Evans, Wendy S Meadows, Mark K Eskandari, Jon S Matsumura, William H Pearce.   

Abstract

OBJECTIVE: Percutaneous treatment of an abdominal aortic aneurysm (AAA) is feasible, but is associated with a unique set of risks. A comparison of Excluder endograft deployment with femoral artery cutdown (FAC) versus percutaneous femoral access (PFA) for treatment of infrarenal AAA was undertaken.
METHODS: A single-institution, controlled, retrospective review was carried out in patients who underwent either bilateral FAC or bilateral PFA for endovascular repair of infrarenal AAA with the Gore bifurcated Excluder endograft between March 1999 and November 2003. To November 2000, 35 patients underwent bilateral FAC; since then, 47 patients have undergone bilateral PFA. All have been followed up for at least 30 days.
RESULTS: Mean AAA size was 5.7 cm in the FAC group and 6.0 cm in the PFA group. During hospitalization there were six access-related complications in the FAC group; three required early surgical intervention. In the PFA group nine perioperative access-related complications occurred, all consisting of either hemorrhage or arterial occlusion; seven required additional intervention, and were recognized and ameliorated while the patient was still in the operating room. At 30-day follow-up there were no additional access-related complications in the PFA group. There were eight other access-related complications in eight additional patients who underwent FAC. In patients undergoing bilateral PFA total operative time was shorter (PFA 139 minutes vs FAC 169 minutes; P =.002), total in-room anesthesia time was less (PFA 201 minutes vs FAC 225 minutes; P <.008), and use of general anesthesia was reduced (P <.001). No significant differences were observed between groups with respect to estimated blood loss (PFA 459 mL vs FAC 389 mL; P =.851).
CONCLUSION: Complete percutaneous treatment of AAA may have some advantages over open femoral artery access, but it is not free from risk. Percutaneous treatment of AAA can be completed successfully in most patients, but should be performed at an institution where conversion to an open procedure can be completed expeditiously if necessary.

Entities:  

Mesh:

Year:  2004        PMID: 15218455     DOI: 10.1016/j.jvs.2004.03.019

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  20 in total

1.  Current status of percutaneous endografting.

Authors:  Bulent Arslan; Ulku C Turba; Saher Sabri; J Fritz Angle; Alan H Matsumoto
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

2.  Ultrasound-guided percutaneous endovascular aneurysm repair success is predicted by access vessel diameter.

Authors:  Rodney P Bensley; Rob Hurks; Zhen Huang; Frank Pomposelli; Allen Hamdan; Mark Wyers; Elliot Chaikof; Marc L Schermerhorn
Journal:  J Vasc Surg       Date:  2012-02-22       Impact factor: 4.268

3.  A single-centre experience of 200 consecutive unselected patients in percutaneous EVAR.

Authors:  Sergio Petronelli; Maria Teresa Zurlo; Silvia Giambersio; Lucia Danieli; Mariaelena Occhipinti
Journal:  Radiol Med       Date:  2014-04-04       Impact factor: 3.469

4.  Percutaneous versus femoral cutdown access for endovascular aneurysm repair.

Authors:  Dominique B Buck; Eleonora G Karthaus; Peter A Soden; Klaas H J Ultee; Joost A van Herwaarden; Frans L Moll; Marc L Schermerhorn
Journal:  J Vasc Surg       Date:  2015-03-28       Impact factor: 4.268

5.  Emergent repair of acute thoracic aortic catastrophes: a comparative analysis.

Authors:  Peter A Naughton; Michael S Park; Mark D Morasch; Heron E Rodriguez; Manuel Garcia-Toca; C Edward Wang; Mark K Eskandari
Journal:  Arch Surg       Date:  2012-03

6.  Endovascular approach to acute aortic trauma.

Authors:  Riyad Karmy-Jones; Desarom Teso; Nicole Jackson; Lisa Ferigno; Robert Bloch
Journal:  World J Radiol       Date:  2009-12-31

7.  Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

Authors:  Antonio E Dager; Rutger-Jan Nuis; Bernardo Caicedo; Jaime A Fonseca; Camilo Arana; Lidsa Cruz; Luis M Benitez; Carlos A Nader; Eduardo Duenas; Eduardo J de Marchena; William W O'Neill; Peter P de Jaegere
Journal:  Tex Heart Inst J       Date:  2012

8.  Canadian experience with percutaneous endovascular aneurysm repair: short-term outcomes.

Authors:  S Marlene Grenon; Joel Gagnon; York N Hsiang; Jerry C Chen
Journal:  Can J Surg       Date:  2009-10       Impact factor: 2.089

Review 9.  Transcatheter Aortic Valve Implantation.

Authors:  S Chris Malaisrie; Adam Iddriss; James D Flaherty; Andrei Churyla
Journal:  Curr Atheroscler Rep       Date:  2016-05       Impact factor: 5.113

Review 10.  Fascia Suture Technique and Suture-mediated Closure Devices: Systematic Review.

Authors:  Georgios Karaolanis; Ioannis D Kostakis; Demetrios Moris; Viktoria-Varvara Palla; Konstantinos G Moulakakis
Journal:  Int J Angiol       Date:  2018-01-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.