Literature DB >> 15205925

Complications of percutaneous vertebroplasty and their prevention.

J D Laredo1, B Hamze.   

Abstract

Complications due to vertebroplasty may be divided into two categories whether or not they are related to polymethylmethacrylate (PMMA) cement leakage from the compressed vertebral body. PMMA leakage is a very frequent occurrence in vertebroplasty is also the main source of complications. Neurological complications are due to cement leakage into the spinal canal and less exceptionally into the intervertebral foramen. The transpedicular needle approach reduces the risk of cement leakage into the foramen. Pulmonary embolism of PMMA may occur when there is a failure to recognize venous migration of cement early during the procedure. Cortical destruction, presence of an epidural soft-tissue mass, highly vascularized lesions, and severe vertebral collapse are factors which increase the rate of complications, which is therefore much higher in metastatic than in osteoporotic vertebral collapse. Prevention of PMMA leakage-related complications is a multifactorial issue including procedure preparation, needle approach and placement, and cement application. The technical refinements which may help reduce the risk of PMMA leakage are reviewed in this article. Experimental data have shown that systemic reactions may occur during vertebroplasty in the absence of cement leakage. These reactions may be partly related to vascular embolism of bone marrow fat. Another controversial issue is a possible increase in the risk of vertebral collapse of adjacent vertebrae following vertebroplasty. Prospective randomized studies are needed to resolve this issue.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15205925     DOI: 10.1007/s00256-004-0776-8

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  44 in total

1.  Innervation of the human vertebral body: a histologic study.

Authors:  M D Antonacci; D R Mody; M H Heggeness
Journal:  J Spinal Disord       Date:  1998-12

2.  Acute bronchospasm associated with polymethylmethacrylate cement.

Authors:  H Y Wong; M I Vidovich
Journal:  Anesthesiology       Date:  1997-09       Impact factor: 7.892

3.  Experimental production of vascular hypotension, and bone marrow and fat embolism with methylmethacrylate cement. Traumatic hypertension of bone.

Authors:  A L Breed
Journal:  Clin Orthop Relat Res       Date:  1974 Jul-Aug       Impact factor: 4.176

4.  Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy.

Authors:  A Gangi; B A Kastler; J L Dietemann
Journal:  AJNR Am J Neuroradiol       Date:  1994-01       Impact factor: 3.825

5.  Biomechanical evaluation of a new bone cement for use in vertebroplasty.

Authors:  S M Belkoff; J M Mathis; E M Erbe; D C Fenton
Journal:  Spine (Phila Pa 1976)       Date:  2000-05-01       Impact factor: 3.468

6.  Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects.

Authors:  M E Jensen; A J Evans; J M Mathis; D F Kallmes; H J Cloft; J E Dion
Journal:  AJNR Am J Neuroradiol       Date:  1997 Nov-Dec       Impact factor: 3.825

7.  Percutaneous vertebroplasty for pain relief and spinal stabilization.

Authors:  J D Barr; M S Barr; T J Lemley; R M McCann
Journal:  Spine (Phila Pa 1976)       Date:  2000-04-15       Impact factor: 3.468

8.  Neuropeptide Y, tyrosine hydroxylase and vasoactive intestinal polypeptide-immunoreactive nerve fibers in the vertebral bodies, discs, dura mater, and spinal ligaments of the rat lumbar spine.

Authors:  M Ahmed; A Bjurholm; A Kreicbergs; M Schultzberg
Journal:  Spine (Phila Pa 1976)       Date:  1993-02       Impact factor: 3.468

9.  Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up.

Authors:  A Cotten; F Dewatre; B Cortet; R Assaker; D Leblond; B Duquesnoy; P Chastanet; J Clarisse
Journal:  Radiology       Date:  1996-08       Impact factor: 11.105

10.  [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty].

Authors:  P Galibert; H Deramond; P Rosat; D Le Gars
Journal:  Neurochirurgie       Date:  1987       Impact factor: 1.553

View more
  42 in total

1.  Role of the supine lateral radiograph of the spine in vertebroplasty for osteoporotic vertebral compression fracture: a prospective study.

Authors:  Meng-Huang Wu; Tsung-Jen Huang; Chin-Chang Cheng; Yen-Yao Li; Robert Wen-Wei Hsu
Journal:  BMC Musculoskelet Disord       Date:  2010-07-19       Impact factor: 2.362

Review 2.  Osteoporotic fractures in older adults.

Authors:  Cathleen S Colón-Emeric; Kenneth G Saag
Journal:  Best Pract Res Clin Rheumatol       Date:  2006-08       Impact factor: 4.098

3.  Percutaneous vertebroplasty in the therapy of osteoporotic vertebral compression fractures: a critical review.

Authors:  K Hochmuth; D Proschek; W Schwarz; M Mack; A A Kurth; T J Vogl
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

4.  Radicular pain after vertebroplasty: complication and prevention.

Authors:  Alexis D Kelekis; Jean-Baptiste Martin
Journal:  Skeletal Radiol       Date:  2005-12       Impact factor: 2.199

Review 5.  Percutaneous Vertebral Augmentation Techniques in Osteoporotic and Traumatic Fractures.

Authors:  Valérie Bousson; Bassam Hamze; Guillaume Odri; Thomas Funck-Brentano; Philippe Orcel; Jean-Denis Laredo
Journal:  Semin Intervent Radiol       Date:  2018-11-05       Impact factor: 1.513

6.  Refracture with cement extrusion following percutaneous vertebroplasty of a large interbody cleft.

Authors:  A L Wagner; E Baskurt
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

7.  New fractures after vertebroplasty: adjacent fractures occur significantly sooner.

Authors:  A T Trout; D F Kallmes; T J Kaufmann
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

8.  Kyphoplasty.

Authors:  David M Kasper
Journal:  Semin Intervent Radiol       Date:  2010-06       Impact factor: 1.513

9.  Pyogenic spondylitis after vertebroplasty - a report of two cases -.

Authors:  Chang Bum Lee; Hyung Sup Kim; Yong Jin Kim
Journal:  Asian Spine J       Date:  2007-12-31

10.  Transpedicle body augmenter for vertebral augmentation in symptomatic multiple osteoporotic compression fractures.

Authors:  Allen Li; Kung-Chia Li; Ching-Hsiang Hsieh
Journal:  Indian J Orthop       Date:  2010-04       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.