Literature DB >> 15198390

Curing depths of a universal hybrid and a flowable resin composite cured with quartz tungsten halogen and light-emitting diode units.

Anders Lindberg1, Anne Peutzfeldt, Jan W V van Dijken.   

Abstract

This in vitro study evaluated curing depths of a universal hybrid resin composite with two viscosities (Tetric Ceram and Tetric Flow) after curing with 6 different quartz tungsten halogen and light-emitting diode curing units. Irradiance (light intensity) of the curing units varied between 200 and 700 mW/cm2. The curing units were used for standard, soft-start, or pulse curing. Curing times were 20 and 40 s for standard curing, 3 + 10 s and 3 + 30 s for pulse curing, and 40 s for soft-start. Resin composite specimens, 5 in each group, with a diameter of 4 mm and a height of 6 mm, were made in brass molds and cured from one side at a distance of 6 mm. After 2 weeks, the specimens were ground longitudinally half through the specimen. Curing depth was then determined by measurement of Wallace hardness for each half millimeter starting at 0.5 mm from the top surface. For all curing units and for both resin composites an increased curing time led to statistically significantly higher depth of cure (P < 0.0005). Tetric Flow showed a statistically significantly higher depth of cure than Tetric Ceram (P < 0.0005). All curing units cured more than 2.0 mm of both composites from a distance of 6 mm at 20 s curing time. The value for 40 s was 3.0 mm. The composite closer to the surface than the depth of cure value was equally well cured with all curing units investigated. There was a significant linear correlation between the determined irradiance of the curing units and the depths of cure obtained (20s: r = 0.89, P < 0.025; 40 s: r = 0.91, P < 0.01).

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15198390     DOI: 10.1080/00016350410006905

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  4 in total

1.  Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure.

Authors:  Anders Lindberg; Anne Peutzfeldt; Jan W V van Dijken
Journal:  Clin Oral Investig       Date:  2005-04-07       Impact factor: 3.573

2.  Evaluation of the curing depth of two translucent composite materials using a halogen and two LED curing units.

Authors:  Olga Polydorou; Alexandros Manolakis; Elmar Hellwig; Petra Hahn
Journal:  Clin Oral Investig       Date:  2007-10-25       Impact factor: 3.573

3.  Effects of occlusal cavity configuration on 3D shrinkage vectors in a flowable composite.

Authors:  Dalia Kaisarly; Moataz El Gezawi; Guangyun Lai; Jian Jin; Peter Rösch; Karl-Heinz Kunzelmann
Journal:  Clin Oral Investig       Date:  2017-12-16       Impact factor: 3.573

4.  Surface energy and wettability of polymers light-cured by two different systems.

Authors:  Fatima Maria Namen; Eduardo Ferrandini; João Galan Junior
Journal:  J Appl Oral Sci       Date:  2011-10       Impact factor: 2.698

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.