A clinical comparison of two cements for levels of post-operative sensitivity in a practice-based setting.

Thomas Hilton1, Deanna Hilton, Ros Randall, Jack L Ferracane.   

Abstract

UNLABELLED: This study compared the post-operative results of cementing full crowns (all metal or PFM) with either a conventional (Fuji I, GC; n=102) or a resin modified GI luting cement (Rely X, 3M/ESPE; n=107).
METHODS: Ten private practitioners fabricated 209 crowns using standardized preparation/luting criteria and randomly assigned cements. Patients self-reported temperature and biting sensitivity, on a 0-10 scale at 24 hours, one week, one month and three months post-cementation. Data were analyzed using t-tests, confirmatory Mann-Whitney tests and Pearson correlations, with a significance level of p < or = 0.05.
RESULTS: Of all patients, 50.7% reported any sensitivity at any time period. Mean sensitivity for all patients on the 10-point scale was 0.52 for temperature and 0.23 for biting. Cements did not differ in cold or biting sensitivity at any time. There were many significant (though low) correlations between the sensitivity measures and age (inverse relationship) and dentin area of preparation (direct). The practice-based format provided a viable alternative to performing clinical research.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15195722

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  Postoperative tooth sensitivity with a new self-adhesive resin cement--a randomized clinical trial.

Authors:  Markus B Blatz; Francis K Mante; Najeed Saleh; Alan M Atlas; Sahurabh Mannan; Fusun Ozer
Journal:  Clin Oral Investig       Date:  2012-07-11       Impact factor: 3.573

2.  The Retentive Strength of Cemented Zirconium Oxide Crowns after Dentin Pretreatment with Desensitizing Paste Containing 8% Arginine and Calcium Carbonate.

Authors:  Raphael Pilo; Noga Harel; Joseph Nissan; Shifra Levartovsky
Journal:  Int J Mol Sci       Date:  2016-03-25       Impact factor: 5.923

3.  Clinical Feasibility of Fully Sintered (Y, Nb)-TZP for CAD-CAM Single-Unit Restoration: A Pilot Study.

Authors:  Ki-Won Jeong; Hyung-In Yoon; Jae-Hyun Lee; In-Sung Luke Yeo; Dae-Joon Kim; Jung-Suk Han
Journal:  Materials (Basel)       Date:  2021-05-23       Impact factor: 3.623

  3 in total