Literature DB >> 15194093

In vivo measurement of total knee replacement wear.

C F Kellett1, A Short, A Price, H S Gill, D W Murray.   

Abstract

Polyethylene wear is one of the most important causes of failure of total knee replacements (TKRs). Currently, wear can only be accurately measured by retrieval studies. There is a need for a method to measure wear accurately in vivo. We have developed a Roentgen stereophotogrammetric analysis (RSA) system that can measure penetration of the metallic femoral component into the polyethylene of the tibia. We have used this system to study six AGC TKRs at 6 years postoperatively and six control AGC TKRs at 2 weeks postoperatively. The mean difference between the RSA measured bearing thickness and the manufacturer's quoted values for the control group was -0.03 mm (S.D. 0.17). The average linear penetration in the study group was 0.8 mm (S.D. 0.46). This was significantly (P<0.0001) different from the control group. The average linear penetration rate was 0.13 mm per year (S.D. 0.08). We would expect the penetration to deepen with time. In young active patients, this could be a cause for concern, particularly with a thin bearing. The current system is accurate enough to measure wear at 5 years post TKR. It has the potential for predicting long-term wear problems with new designs of TKR and new materials within 2 years.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15194093     DOI: 10.1016/S0968-0160(03)00070-X

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  4 in total

1.  Electromyography-Driven Forward Dynamics Simulation to Estimate In Vivo Joint Contact Forces During Normal, Smooth, and Bouncy Gaits.

Authors:  Swithin S Razu; Trent M Guess
Journal:  J Biomech Eng       Date:  2018-07-01       Impact factor: 2.097

2.  Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA.

Authors:  Matthew G Teeter; Jacob Wihlidal; Richard W McCalden; Xunhua Yuan; Steven J MacDonald; Brent A Lanting; Douglas D Naudie
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

Review 3.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

4.  Long-term in vivo wear of different bearing types used for the Oxford Unicompartmental Knee Replacement.

Authors:  Hasan R Mohammad; Stefano Campi; James A Kennedy; Andrew Judge; David W Murray; Stephen J Mellon
Journal:  Bone Joint Res       Date:  2019-12-03       Impact factor: 5.853

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.