Literature DB >> 1519283

Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults.

M Schöning1, J Walter.   

Abstract

BACKGROUND AND
PURPOSE: The transcranial color duplex sonography technique was applied to the vertebrobasilar-posterior system to provide normal data for clinical application.
METHODS: The intracranial posterior circulation was studied in 49 healthy volunteers (mean +/- SD age, 35 +/- 12 years) by a transcranial and suboccipital approach with a 2.0-MHz sector transducer of a computed sonography system.
RESULTS: The posterior cerebral artery and the vertebrobasilar system were depicted clearly in the color Doppler mode. Pulsed Doppler signals could be recorded in the posterior cerebral (100%), basilar (92%), and vertebral arteries (89%). The following normal values were provided for all vessels: systolic peak, end-diastolic maximum, time-averaged, and time-averaged maximum velocities; resistance and pulsatility indexes; and a spectral broadening index. Mean +/- SD values were 45.9 +/- 9.6, 45.5 +/- 10.8, and 39.2 +/- 10.6 cm/sec for time-averaged maximum velocity, and 28.3 +/- 6.5, 30.6 +/- 7.2, and 24.7 +/- 8.4 cm/sec for time-averaged velocity in the posterior cerebral, basilar, and vertebral arteries, respectively. In a reproducibility study, duplex measurements of the posterior cerebral arteries were repeated in 27 subjects. The correlation between the two examiners was high (r = 0.56, p less than or equal to 0.0001 for time-averaged maximum velocity).
CONCLUSIONS: Color duplex sonography of the vertebrobasilar-posterior system is a new, noninvasive, bedside investigative technique. It permits visualization of artery flow in real time, relating these to adjacent brain and cranial structures, as well as angle-corrected duplex measurement of "true" flow velocities at defined sites of the vessels. Thus, it will open new diagnostic possibilities in disorders of the posterior circulation.

Mesh:

Year:  1992        PMID: 1519283     DOI: 10.1161/01.str.23.9.1280

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  6 in total

1.  Vertebrobasilar transcranial color-coded duplex ultrasonography: improvement with echo enhancement.

Authors:  Erwin Stolz; Martin Nückel; Irene Mendes; Tibo Gerriets; Manfred Kaps
Journal:  AJNR Am J Neuroradiol       Date:  2002 Jun-Jul       Impact factor: 3.825

Review 2.  The application of ultrasound in the management of cerebral arteriovenous malformation.

Authors:  Bing Fu; Ji-Zong Zhao; Lan-Bing Yu
Journal:  Neurosci Bull       Date:  2008-12       Impact factor: 5.203

3.  Diagnostic criteria for transcranial colour-coded duplex sonography evaluation of cross-flow through the circle of Willis in unilateral obstructive carotid artery disease.

Authors:  R W Baumgartner; I Baumgartner; G Schroth
Journal:  J Neurol       Date:  1996-07       Impact factor: 4.849

4.  Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI.

Authors:  Stephan Meckel; Lorenz Leitner; Leo H Bonati; Francesco Santini; Tilman Schubert; Aurelien F Stalder; Philippe Lyrer; Michael Markl; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2012-11-10       Impact factor: 2.804

5.  Vertebral Artery Blood flow Velocity Changes Associated with Cervical Spine rotation: A Meta-Analysis of the Evidence with implications for Professional Practice.

Authors:  Jeanette Mitchell
Journal:  J Man Manip Ther       Date:  2009

6.  Can Transcranial Color Doppler Spectral Signatures be a Novel Biomarker for Monitoring Cerebrovascular Autoregulation and Intracranial Pressure? A Speculative Synthesis.

Authors:  Sandhya Mangalore; Rakshith Srinivasa; Alangar Sathyaranjandas Hegde; Rangashetty Srinivasa
Journal:  Ann Indian Acad Neurol       Date:  2017 Jul-Sep       Impact factor: 1.383

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.