Literature DB >> 15191148

Sampling and aliasing consequences of quarter-detector offset use in helical CT.

Patrick J La Rivière1, Xiaochuan Pan.   

Abstract

In this paper, the sampling and aliasing consequences of employing a quarter-detector-offset (QDO) in helical computed tomography (CT) are analyzed. QDO is often used in conventional CT to reduce in-plane aliasing by eliminating data redundancies to improve radial sampling. In helical CT, these same redundancies are exploited to improve longitudinal sampling and so it might seem ill-advised to employ QDO. The relative merit of the two geometries for helical CT is studied by conducting a multidimensional sampling analysis of projection-space sampling as well as a Fourier crosstalk analysis of crosstalk among the object's Fourier basis components. Both a standard fanbeam helical CT geometry and a hypothetical parallel-beam CT geometry, which helps illuminate the more complicated fanbeam results, are analyzed. Using the sampling analysis, it was found that the use of QDO leads to very different spectral tiling than arise when not using QDO. However, due to the shape of the essential support of the projection data spectra that arises in practice, both configurations lead to very similar or identical amounts of spectral overlap. This perspective also predicts the spatially variant longitudinal aliasing that has been observed in helical CT. The crosstalk results were consistent with those of the multidimensional sampling analysis. Thus, from the standpoint of aliasing and crosstalk, no compelling difference is found between the two geometries.

Mesh:

Year:  2004        PMID: 15191148     DOI: 10.1109/tmi.2004.826950

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  7 in total

1.  The feasibility of an inverse geometry CT system with stationary source arrays.

Authors:  Scott S Hsieh; Joseph A Heanue; Tobias Funk; Waldo S Hinshaw; Brian P Wilfley; Edward G Solomon; Norbert J Pelc
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

2.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

3.  Technical Note: FreeCT_wFBP: A robust, efficient, open-source implementation of weighted filtered backprojection for helical, fan-beam CT.

Authors:  John Hoffman; Stefano Young; Frédéric Noo; Michael McNitt-Gray
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

4.  Robust regression-based estimation of isocenter offset with subpixel precision in tomographic image reconstruction.

Authors:  Xuelin Cui; Lamine Mili; Ibrahim Bechwati; Shouhua Luo
Journal:  J Med Imaging (Bellingham)       Date:  2019-11-15

5.  Quantifying admissible undersampling for sparsity-exploiting iterative image reconstruction in X-ray CT.

Authors:  Jakob S Jørgensen; Emil Y Sidky; Xiaochuan Pan
Journal:  IEEE Trans Med Imaging       Date:  2012-11-27       Impact factor: 10.048

6.  High fidelity system modeling for high quality image reconstruction in clinical CT.

Authors:  Synho Do; William Clem Karl; Sarabjeet Singh; Mannudeep Kalra; Tom Brady; Ellie Shin; Homer Pien
Journal:  PLoS One       Date:  2014-11-12       Impact factor: 3.240

7.  A Subband-Specific Deconvolution Model for MTF Improvement in CT.

Authors:  Seokmin Han; Kihwan Choi; Sang Wook Yoo
Journal:  J Healthc Eng       Date:  2017-10-25       Impact factor: 2.682

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.