Literature DB >> 15190566

Jumbo cup or high hip center: is bigger better?

Kenneth A Gustke1.   

Abstract

A jumbo cup and a high hip center cup placement are 2 options in the revision of loose acetabular components associated with bone loss. They allow biologic attachment, which is required for long-term fixation. They are easier to use than cages. In my personal series of 564 acetabular revisions from 1986 to 2001, standard-size porous cups with a high hip center were used in 42 (7%) of the cases. Jumbo cups were used in 166 (29%) of the cases. Nineteen percent of the jumbo cups also were placed at a high hip center. The majority of these cups were placed into combined segmental and cavitary defects. The average follow-up was 6.1 years. One jumbo cup and 1 high hip center standard cup were revised for aseptic loosening (1%). The 5-year and 10-year survival rates for shell revision were 95% and 87%, respectively.

Entities:  

Mesh:

Year:  2004        PMID: 15190566     DOI: 10.1016/j.arth.2004.02.012

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  18 in total

1.  [Revision implants of the future: trends and new developments].

Authors:  S Winkler; F-X Köck; C Baier; H-R Springorum; A Beifuss; P Lechler; J Grifka; J Schaumburger
Journal:  Orthopade       Date:  2012-01       Impact factor: 1.087

2.  Do jumbo cups cause hip center elevation in revision THA? A computer simulation.

Authors:  Chima Nwankwo; Nick N Dong; Christopher D Heffernan; Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

3.  [Treatment of acetabular bone defects in revision hip arthroplasty using the Revisio-System].

Authors:  M Hoberg; B M Holzapfel; A F Steinert; F Kratzer; M Walcher; M Rudert
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

4.  Biological fixation of total hip arthroplasty: Facts and factors.

Authors:  Raju Karuppal
Journal:  J Orthop       Date:  2016-06-15

Review 5.  [Allogeneic bone transplantation in hip revision surgery : Indications and potential for reconstruction].

Authors:  G A Ahmed; B Ishaque; M Rickert; C Fölsch
Journal:  Orthopade       Date:  2018-01       Impact factor: 1.087

6.  Novel Acetabular Cup for Revision THA Improves Hip Center of Rotation: A Radiographic Evaluation.

Authors:  Anton Khlopas; Morad Chughtai; Randa K Elmallah; David Hip-Flores; Arthur L Malkani; Steven F Harwin; Michael A Mont; Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

7.  Cavitary acetabular defects treated with morselized cancellous bone graft and cementless cups.

Authors:  G C T Pereira; E N Kubiak; B Levine; F S Chen; P E Di Cesare
Journal:  Int Orthop       Date:  2006-09-19       Impact factor: 3.075

8.  Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years.

Authors:  Stefan Lakemeier; Guenter Aurand; Nina Timmesfeld; Thomas J Heyse; Susanne Fuchs-Winkelmann; Markus D Schofer
Journal:  BMC Musculoskelet Disord       Date:  2010-05-27       Impact factor: 2.362

9.  Do jumbo cups cause hip center elevation in revision THA? A radiographic evaluation.

Authors:  Chima D Nwankwo; Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2014-04-18       Impact factor: 4.176

10.  High hip center technique using a biconical threaded Zweymüller cup in osteoarthritis secondary to congenital hip disease.

Authors:  Nikolaos A Christodoulou; Konstantinos P Dialetis; Athanasios N Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-01-05       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.